78 Parameters
173.27
Line filter temperature
Line filter temperature.
-
-80 … 150 °C
1 = 1 °C
173.30
SPD installed
Indicates whether a Surge Protection Device
(SPD) is installed.
• If a SPD is detected in the system, the
parameter is automatically set to
Yes
.
• If SPD is permanently removed from system,
manually set this parameter to
No
. Otherwise,
a warning is indicated at the time of inverter
power up.
No
No
SPD is not detected.
0
Yes
SPD is detected.
1
173.31
Ground impedance parallel Shows measured ground impedance.
0 MOhm
-1000 … 1000 MOhm
- /
1000 = 1 MOhm
173.32
Ground current RMS
Shows residual ground current as measured by
the internal residual current monitoring unit
(RCMU).
-
0...1000 mA
1 = 1 mA
173.33
Ground current resistive
Shows the resistive or DC part of the residual
ground current as measured by the RCMU.
-
-1000...1000 mA
1 = 1 mA
173.34
RCMU test current
Shows test current used for self-test of the
RCMU.
0.0 mA
-325.0 ... +325.0 mA
10 = 1 mA
173.36
Ground current meas. diff
RMS
Shows difference between monitoring channels.
The system uses two separate channels for
obtaining the residual current reading from the
RCMU. A fault is raised if the difference is too big.
0
0.0 ... 1000.0 mA
1 = 1 /
10 = 1 mA
173.80
Control unit comm status
Shows status of the communication link between
the PVS-AP-L control unit and the inverter
firmware.
0
0
Link is down
0
1
Link is up
1
173.81
Control unit service status
Packet counter which counts application service
transactions between the PVS-AP-L control unit
and the inverter firmware. The counter wraps
around to zero after 65535. The counter
increments rapidly when the control unit is
operated by the user and slows down to one
increment per minute when the control unit has
turned on the screen saver.
0
0...65535
1 = 1
No.
Name/Value/Range
Description
Default
FbEq (16b/32b)
Содержание PRO-33.0-TL Series
Страница 1: ...ABB solar inverters Service menu guide PRO 33 0 TL string inverters ...
Страница 4: ......
Страница 8: ...8 ...
Страница 12: ...12 Service menu ...
Страница 36: ...36 Program features ...
Страница 100: ...100 Parameters ...
Страница 112: ...112 Tools ...
Страница 121: ......
Страница 122: ...www abb com solarinverters Contact us 3AXD50000015823 Rev C EN 2017 06 29 ...