44 Parameters
No.
Name/Value/Range
Description
Default
FbEq (16b/32b)
114 Extension I/O module 1
114.01
Option module 1 type
Activates and specifies the type of I/O extension
module 1.
None
None
None
0
FIO-01
FIO-01
1
FIO-11
FIO-11
2
114.03
Option module 1 status
Displays the status of I/O extension module 1.
No option
No option
No module detected in the specified slot.
0
No communication
A module has been detected but cannot be
communicated with.
1
Unknown
The module type is unknown.
2
FIO-01
An FIO-01 module has been detected and is
active.
15
FIO-11
An FIO-11 module has been detected and is
active.
20
114.05
DIO status
(
is FIO-01 or FIO-11.
)
Displays the status of the digital input/outputs on
the extension module. The activation/
deactivation delays (if any are specified) are
ignored. Bit 0 indicates the status of DIO1.
Note
: The number of active bits in this parameter
depends on the number of digital input/outputs on
the extension module.
Example
: 00001001b = DIO1 and DIO4 are on,
remainder are off.
This parameter is read-only.
-
1 = 1
114.09
DIO1 configuration
(
is FIO-01 or FIO-11.
)
Selects whether DIO1 of the extension module is
used as a digital input or output.
Input
Output
DIO1 is used as a digital output.
0
Input
DIO1 is used as a digital input.
1
114.11
DIO1 output source
(
is FIO-01 or FIO-11.
)
Selects an inverter signal to be connected to
digital input/output DIO1 of the extension module
when parameter
is set
to Output.
Off
Off
0
Always On
1
Fault
Relay output activation when fault.
2
No fault
Relay output activation when no fault.
3
Grid connected
Relay output activation when grid connected.
4
Grid not connected
Relay output activation when grid not connected. 5
Power level 20%
Relay output activation when output power level
over 20% of rated power.
6
Power level 40%
Relay output activation when output power level
over 40% of rated power.
7
Содержание PRO-33.0-TL Series
Страница 1: ...ABB solar inverters Service menu guide PRO 33 0 TL string inverters ...
Страница 4: ......
Страница 8: ...8 ...
Страница 12: ...12 Service menu ...
Страница 36: ...36 Program features ...
Страница 100: ...100 Parameters ...
Страница 112: ...112 Tools ...
Страница 121: ......
Страница 122: ...www abb com solarinverters Contact us 3AXD50000015823 Rev C EN 2017 06 29 ...