![ABB PRO-33.0-TL Series Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/abb/pro-33-0-tl-series/pro-33-0-tl-series_service-manual_3045376045.webp)
Parameters 45
Power level 70%
Relay output activation when output power level
over 70% of rated power.
8
114.14
DIO2 configuration
(
Visible only when parameter
is FIO-01 or FIO-11.
)
Selects whether DIO2 of the extension module is
used as a digital input or output.
Input
Output
DIO2 is used as a digital output.
0
Input
DIO2 is used as a digital input.
1
114.16
DIO2 output source
(
Visible only when parameter
is FIO-01 or FIO-11.
)
Selects an inverter signal to be connected to
digital input/output DIO2 of the extension module
when parameter
is set
to Output. For the available selections, see
parameter
.
Off
114.19
DIO3 configuration
(
Visible only when parameter
is FIO-01.
)
Selects whether DIO3 of the extension module is
used as a digital input or output.
No action
Output
DIO3 is used as a digital output.
0
Input
DIO3 is used as a digital input.
1
114.21
DIO3 output source
(
Visible onlt when parameter
is FIO-01.
)
Selects an inverter signal to be connected to
digital input/output DIO3 of the extension module
when parameter
is set
to Output. For the available selections, see
parameter
.
Off
114.24
DIO4 configuration
(
Visible only when parameter
is FIO-01
.)
Selects whether DIO4 of the extension module is
used as a digital input or output.
Input
Output
DIO4 is used as a digital output.
0
Input
DIO4 is used as a digital input.
1
114.26
DIO4 output source
(
Visible only when parameter
is FIO-01.
)
Selects an inverter signal to be connected to
digital input/output DIO4 of the extension module
when parameter
is set
to Output. For the available selections, see
parameter
.
Off
114.26
AI1 actual value
(
Visible only when parameter
is FIO-11.
)
Displays the value of analog input AI1 in mA or V
(depending on whether the input is set to current
or voltage). This parameter is read-only.
-
No.
Name/Value/Range
Description
Default
FbEq (16b/32b)
Содержание PRO-33.0-TL Series
Страница 1: ...ABB solar inverters Service menu guide PRO 33 0 TL string inverters ...
Страница 4: ......
Страница 8: ...8 ...
Страница 12: ...12 Service menu ...
Страница 36: ...36 Program features ...
Страница 100: ...100 Parameters ...
Страница 112: ...112 Tools ...
Страница 121: ......
Страница 122: ...www abb com solarinverters Contact us 3AXD50000015823 Rev C EN 2017 06 29 ...