TROUBLESHOOTING
ERROR MESSAGES AND CORRECTIVE ACTION
6 - 2
WBPEEUI110504A0
Table 6-1. Error Messages
Message
Fail
Mode
Probable Cause
Corrective Action
Calibration required
No
Cell not calibrated with
present amplifier board.
Calibrate transmitter.
Cannot save, configura-
tion too large
No
Transmitter type not sup-
ported by Type STT terminal
firmware revision level.
Consult Bailey Controls Company
regarding latest Type STT terminal
firmware revision.
Cell characterization
board EEPROM failure
Yes
Damage to cell characteriza-
tion board.
Turn Type STT terminal off and then
on. If error still exists after reset,
replace cell and characterization board
assembly (
).
Cell temperature over
alarm
No
Cell temperature under/over
alarm limit.
Correct temperature problem.
Cell temperature under
alarm
Change alarm value. Refer to
STT Smart Transmitter Terminal
Instruction.
Cell temperature over
limit
No
Cell temperature input
exceeds upper factory limit.
Remove source of temperature
extreme.
Cell temperature under
limit
No
Cell temperature input
exceeds lower factory limit.
Remove source of temperature
extreme.
Config “tagname” already
exists
No
Attempted to copy configura-
tion to cartridge or transmitter
where it already exists.
Erase old configuration before copying
new one. Refer to
Transmitter Terminal Instruction.
Damaged cell or charac-
terization board
Yes
Cell or characterization board
disconnected.
Make sure cell, characterization board,
and amplifier assembly are mounted
properly.
Cell or characterization board
damaged.
Replace cell and characterization
board assembly (
).
Dynamic temperature
measurement failure
No
Dynamic temperature input
exceeded limits set at factory.
Output may no longer be accurate.
Remove source of temperature shift.
Electronics temperature
measurement failure
No
Hardware failure of on-board
temperature sensor.
Replace amplifier assembly
(
).
Electronic temperature
out of range
No
Temperature inside electron-
ics housing exceeds limit set
at factory.
Remove source of temperature
extreme.
Error! Attempt to config-
ure duplicate address
No
Attempt was made to assign
analog mode transmitter
address on FBM.
Be sure transmitter is in correct mode
(analog or digital). Use VIEW key on
Type STT terminal to verify mode.
Refer to
Terminal Instruction for details.
Attempt was made to assign
digital mode transmitter to
occupied FBM address.
Assign transmitter to unoccupied
address or channel number of FBM.
Содержание Platinum standard Series
Страница 1: ......