Note/Illustration
Action
Location of wrist strap button:
xx1800000683
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
2
Reconnect and secure the screw:
•
K6.X4, K6.X5 - SMB.
3
Screws: Torx pan head screw M4x8 (4 pcs)
xx1800000476
Fit the axis computer bracket and secure
the screws.
4
Reconnect:
•
K6.X11 - A1.X3
•
K6.X2 - A2.X9
•
K6.X1 - K2.X3
5
Refitting the small fan
Note/Illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
Continues on next page
338
Product manual - OmniCore C30
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.2.9 Replacing the main computer
Continued