8
7
6
5
4
3
2
1
xx1800000556
Description
Name
Pin
24V_IO_EXT
24V_IO_EXT_1
1
0V_IO_EXT
0V_IO_EXT_1
2
24V_IO_EXT
24V_IO_EXT_2
3
0V_IO_EXT
0V_IO_EXT_2
4
24V_IO_EXT
24V_IO_EXT_3
5
0V_IO_EXT
0V_IO_EXT_3
6
24V_IO_EXT
24V_IO_EXT_4
7
0V_IO_EXT
0V_IO_EXT_4
8
24V_IO_EXT is the 24 V power supply for the customer. The characteristics are
shown in the following table.
Value
Parameter
24V DC
Voltage
-3% ~ +10%
Voltage tolerance
3 A
Max output current
Note
For IRB 14050, the auxiliary 24V DC power connector for electronics on the
Ethernet floor cable should be connected to X19 on the front panel of the
controller.
Connector X20
Description
Customer optional power input (Not available)
Connection
Weidmüller BCF 3.81/06/180F
Type
BCF 3.81/06/180F SN BK BX 6 Pins
3HAC064738-001
Article number
Continues on next page
Product manual - OmniCore C30
119
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.8 Descriptions for connectors
Continued