56
L ST 3 0 0 |
CO M PAC T U LT R A S O N I C L E V EL T R A N SM I T T ER | L S T 3 0 0 – EN R E V. E
IMPORTANT (NOTE)
“F8” digit means that customers choose FM US or FM C Non
incendive or Intrinsically Safe method of protection on the
product .
Dedicated check box is to be marked by the manufacturer or
customers .
IMPORTANT (NOTE) – Note for transmitter with combined
approval
Before installation of the transmitter, customers should
permanently mark their chosen Protection Concept on the
safety label . The transmitter can only be used according to this
Protection Concept for the whole life .
If two or more types of protection box (on the safety label) are
permanently marked, the transmitter must be removed from
hazardous classified locations .
The selected Type of Protection is allowed to be changed only
by the manufacturer after a new satisfactory assessment .
NEPSI approval design for China (Non Sparking)
For detailed information, refer to section “Meter design for
NEPSI non sparking, ATEX/IECEx energy limited (Zone 2 /22),
cFMus division 2, Zone 2/22” .
NEPSI approval design for China (Intrinsically Safe)
GYJXXXXXX
For detailed information, refer to section “Meter design for
NEPSI intrinsic safety, ATEX/IECEx intrinsic safety (Zone 0 /20),
and cFMus division 1, Zone 0/20” .
EC type-examination certificate FM15ATEX0064X
Designation:
II 3 G Ex nA IIC T6 . . .T4 Gc - II 3 D Ex tc IIIC T85°C
For electrical parameters, refer to cert, FM15ATEX0064X
For detailed information, refer to section “Meter design for
NEPSI non sparking, ATEX/IECEx energy limited (Zone 2 /22),
cFMus division 2, Zone 2/22” .
Certificate of conformity IECEx FME 15 . 0010X
Designation:
Ex nA IIC T6 . . .T4 Gc - Ex tc IIIC T85°C
For electrical parameters, refer to cert, IECEx FME 15 .0010X
For detailed information, refer to section “Meter design for
NEPSI non sparking, ATEX/IECEx energy limited (Zone 2 /22),
cFMus division 2, Zone 2/22” .
EC type-examination certificate FM15ATEX0063X
Designation:
II 1 G Ex ia IIC T6 . . .T4 Ga - II 1 D Ex ia IIIC T85° C
For electrical parameters, refer to cert, FM15ATEX0063X
For detailed information, refer to section “Meter design for
NEPSI intrinsic safety, ATEX/IECEx intrinsic safety (Zone 0 /20),
and cFMus division 1, Zone 0/20” .
Certificate of conformity IECEx FME 15 . 0010X
Designation:
Ex ia IIC T6 . . .T4 Ga - Ex ia IIIC T85° C
For electrical parameters, refer to cert, IECEx FME 15 .0010X
For detailed information, refer to section “Meter design for
NEPSI intrinsic safety, ATEX/IECEx intrinsic safety (Zone 0 /20),
and cFMus division 1, Zone 0/20” .
FM approval design for the USA and Canada (Non Incendive)
CL I, ZONE 2 AEx/Ex nA IIC T6 . . .T4
CL I/DIV 2/GP ABCD
NI CL I/DIV 2/GP ABCD
DIP CL II, III/DIV 2/GP EFG
For detailed information, refer to section “Meter design for
NEPSI non sparking, ATEX/IECEx energy limited (Zone 2 /22),
cFMus division 2, Zone 2/22” .
FM approval design for the USA and Canada (Intrinsically
Safe)
IS/Sec . Intrinseque (Entity) CL I
ZONE 0 AEx/Ex ia IIC T6 . . .T4
CL I/DIV 1/GP ABCD IS - CL II,III DIV 1/GP EFG
IS Control Drawing number: 3KXL065035U0009
For detailed information, refer to section “Meter design for
NEPSI intrinsic safety, ATEX/IECEx intrinsic safety (Zone 0 /20),
and cFMus division 1, Zone 0/20” .
Содержание LST300 Series
Страница 26: ...26 LST300 COMPACT ULTR ASONIC LEVEL TR ANSMITTER LST300 EN REV E...
Страница 27: ...LST300 COMPACT ULTR ASONIC LEVEL TR ANSMITTER LST300 EN REV E 27...
Страница 28: ...28 LST300 COMPACT ULTR ASONIC LEVEL TR ANSMITTER LST300 EN REV E...
Страница 59: ...LST300 COMPACT ULTR ASONIC LEVEL TR ANSMITTER LST300 EN REV E 59 Note...