5.2 Fine calibration
General
This procedure must be applied at the first start or after mechanical intervention
(motor change, gearbox).
Required equipment
Note
Art. No.
Equipment
Φ
8 calibration pin
3HAC054533-001
Calibration tool
Fine calibrating
Illustration/Note
Action
Using the FlexPendant, jog the carriage close
to the calibration gauge position.
1
xx1400000570
A: Calibration notch on the carriage
B: Calibration hole on the section
Move the track until the calibration notch on
the carriage line up with the calibration hole
on the section.
2
Insert the calibration pin. A dowel pin diameter
8mm can also be used.
3
Tap
ABB
on the top left of the FlexPendant.
4
Tap
Calibration
.
5
Select the desired mechanical unit.
6
Tap
Fine calibration
.
7
Select the desired axis.
8
Tap
Calibrate
.
9
264
Product manual - IRBT 2005
3HAC051130-001 Revision: F
© Copyright 2015 - 2018 ABB. All rights reserved.
5 Calibration
5.2 Fine calibration
Содержание IRBT 2005
Страница 1: ...ROBOTICS Product manual IRBT 2005 ...
Страница 2: ...Trace back information Workspace R18 2 version a15 Checked in 2018 10 30 Skribenta version 5 3 012 ...
Страница 8: ...This page is intentionally left blank ...
Страница 44: ...This page is intentionally left blank ...
Страница 148: ...This page is intentionally left blank ...
Страница 284: ...This page is intentionally left blank ...
Страница 286: ...This page is intentionally left blank ...
Страница 289: ......