Note
Action
Connect the motor cables.
Note
Connect in accordance with the markings
on the connectors.
3
Tightening torque: 1 Nm
Fit a screw to the power connector.
Note
The purpose of the screw is to secure the
mating of the connectors and the position-
ing of the connector in the connection box.
It is normal that the connector can be
moved back and forth after the screw has
been tightened according to the torque
specification and, in some connection
boxes, that the screw is not even fully inser-
ted when it bottoms.
4
xx2200001736
Continues on next page
Product manual - IRB 6710
359
3HAC085695-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.7.1 Replacing the axis-1 motor
Continued