
Note
Action
Tightening torque: 1 Nm
Connect the power cable connector and
secure with a screw.
3
xx2200001733
Connect in accordance with the markings
on the connectors.
Note
The purpose of the screw is to secure the
mating of the connectors and the position-
ing of the connector in the connection box.
It is normal that the connector can be
moved back and forth after the screw has
been tightened according to the torque
specification and, in some connection
boxes, that the screw is not even fully inser-
ted when it bottoms.
xx2200001734
Connect the signal cable connector.
Connect in accordance with the markings
on the connectors.
4
Connection box cover with gasket:
3HAC072863-003
Inspect the gasket.
Replace if damaged.
5
xx2200002141
Continues on next page
Product manual - IRB 6710
327
3HAC085695-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.6.2 Refitting the cable harness
Continued
Содержание IRB 6710
Страница 1: ...ROBOTICS Product manual IRB 6710 ...
Страница 2: ...Trace back information Workspace 23B version a13 Checked in 2023 06 21 Skribenta version 5 5 019 ...
Страница 8: ...This page is intentionally left blank ...
Страница 14: ...This page is intentionally left blank ...
Страница 36: ...This page is intentionally left blank ...
Страница 584: ...This page is intentionally left blank ...
Страница 614: ...This page is intentionally left blank ...
Страница 634: ...This page is intentionally left blank ...
Страница 639: ......