Note
Action
xx2200001791
Check the cabling going through the protec-
tion tube, to detect possible cable chafing,
by using your hands inside the tube to feel
the cables. Ensure that the cables are un-
damaged.
Remove any objects that may cause pos-
sible cable chafing.
Replace damaged cabling, if any.
CAUTION
Sharp debris might occur. Always wear
protective gloves.
6
See
Replace the cable harness if wear, cracks
or damage is detected.
7
108
Product manual - IRB 6710
3HAC085695-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
4 Maintenance
4.3.3 Inspecting the cable harness
Continued