
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded
space.
3
Retrieving access to the wrist cabling
Use this procedure to remove the wrist cover.
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx1400000355
If DressPack is installed:
•
Remove the bracket with the com-
plete ball joint housing still fitted, as
shown in the figure.
This is done to be able to reach the two
hidden screws that secure the wrist cover.
2
Continues on next page
Product manual - IRB 6710
233
3HAC085695-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the arm house cover including the axis-4 cassette sealing
Continued
Содержание IRB 6710
Страница 1: ...ROBOTICS Product manual IRB 6710 ...
Страница 2: ...Trace back information Workspace 23B version a13 Checked in 2023 06 21 Skribenta version 5 5 019 ...
Страница 8: ...This page is intentionally left blank ...
Страница 14: ...This page is intentionally left blank ...
Страница 36: ...This page is intentionally left blank ...
Страница 584: ...This page is intentionally left blank ...
Страница 614: ...This page is intentionally left blank ...
Страница 634: ...This page is intentionally left blank ...
Страница 639: ......