Note
Action
xx0700000626
A Calibration device
Push the upper arm very gently
against the calibration device.
Note
Always calibrate one axis a time,
starting with axis 1.
5
The upper arm is now in calibration position.
When the upper arm reaches the cal-
ibration device, apply the brake.
6
Described in section
Store the resolver value by doing a
fine calibration.
7
Release the brakes and gently pull the
calibrated upper arm in to a horizontal
position.
8
Return to step
, and proceed with
axis 2 and 3.
9
244
Product manual - IRB 360
3HAC030005-001 Revision: U
© Copyright 2008-2018 ABB. All rights reserved.
5 Calibration information
5.5 Calibrating axis 1-3
Continued