Note
Action
How to drain oil is detailed in section
•
Changing the oil, axis 1 gearbox on
floor mounted robots on page 150
Drain the axis-1 gearbox.
Note
Draining is time-consuming.
Elapsed time varies depending on the tem-
perature of the oil.
4
How to remove the cable harness in base
and frame is detailed in sections:
•
Removing cable harness in base
on page 198
•
Removing cable harness in frame
on page 203
•
Removing cable harness in lower
arm and armhouse on page 204
Remove the
cable harness
in the base, the
frame and the lower arm of the robot.
Tip
Wrap up the cabling against the frame to
keep it undamaged during the remaining
work.
5
Dimensions are specified in
.
A
B
xx1800001211
A Roundsling 1.5 m
B Roundsling 2 m
Secure the robot with
roundslings
in an
overhead crane.
Stretch the roundslings so that the robot
weight is secured when removing founda-
tion bolts in next step.
6
CAUTION
The IRB 2600/IRB 2600 ID robot weighs 280
kg.
All lifting accessories used must be sized
accordingly!
7
Remove the bolts that secure the robot to
the foundation.
8
Continues on next page
292
Product manual - IRB 2600
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
4 Repair
4.6.2 Replacing the base
Continued
Содержание IRB 2600 Series
Страница 1: ...ROBOTICS Product manual IRB 2600 ...
Страница 2: ...Trace back information Workspace R18 2 version a18 Checked in 2018 11 20 Skribenta version 5 3 012 ...
Страница 390: ...This page is intentionally left blank ...
Страница 432: ...This page is intentionally left blank ...
Страница 446: ...This page is intentionally left blank ...
Страница 452: ......
Страница 453: ......