Information
Action
xx1500000318
Apply load F=40N downwards on another
side, as shown in the figure.
Remove the load and make a note of the
value from the dynamometer, as value
b2
.
11
The maximum play allowed is:
•
IRB 1600ID-4/1.5: 0.25 mm
•
IRB 1660ID-X/1.55: 0.20 mm
Calculate the play in the axis as
b1
+
b2
.
The values of
b1
and
b2
are absolute val-
ues.
12
Turn on power.
13
Turn axis 6 to +180°.
14
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
15
Repeat
to
.
16
238
Product manual - IRB 1600/1660
3HAC026660-001 Revision: W
© Copyright 2006-2018 ABB. All rights reserved.
4 Repair
4.4.13 Measuring the play 1600ID/1660ID, axis 6
Continued
Содержание IRB 1660