Operation Manual / TPL69-A10 / -A30 ... TPL77-A10 / -A30
5 Maintenance / 5.4 Cleaning turbine blades and nozzle ring in opera-
tion
© Copyright 2020 . All rights reserved.
HZTL2481_EN
Rev.D
March 2020
Wet cleaning parameters for turbine and nozzle ring
Table of cleaning para-
meters
Product
Maximum tem-
perature at start
of cleaning pro-
cess
T
TI
[°C]
Injection time
t
i
[min]
Water flow rate per tur-
bocharger at p
Water
= 2 bar
M
W
[l/min]
TPL69-A
430
10
18
TPL73-A
24
TPL77-A
37
Page
61
/
134