The following table lists terms and abbreviations users should be familiar with when using this manual. Some of
the terms and abbreviations used in the manual are unique to ABB and might differ from the common use.
Abbreviation/Term
Meaning
LV
Low Voltage. Voltage level up to 1000 Vac or 1500 Vdc.
MV
Medium Voltage. Voltage level between 1 kVac and 35 kVac.
PCS120
Power Conversion System 120. PCS120 is the product platform for the ABB power condi-
tioning products.
PEBB
Power Electronic Building Block.
PE120-N
Platform Enclosure 120. PE120 is the enclosure that contains several PEBB modules. The
product has three enclosure designated as PE120-1, PE120-2 & PE120-3.
DCT
Direct Current Termination. DCT is an enclosure where the energy storage cables are ter-
minated and connected to the MV UPS PE120 cabinets.
APS
Auxiliary Power Supply. APS is an enclosure that contains the MV UPS switched-mode
power supplies, remote input/output modules, control circuits and auxiliary transformer.
ILR
Isolating Line Reactor. ILR is a medium voltage impedance connected in series, between
the grid and the load.
CXF
Coupling Transformer. CXF is a transformer that couples the medium voltage network to
the low voltage power converters.
Sin
Input Switch. Represents the designation of the input circuit breaker connecting the MV
UPS to the grid.
Sout
Output Switch. Represents the designation of the output circuit breaker connecting the
MV UPS to the load.
Sabp
Automatic Bypass Switch. Represents the designation of the bypass circuit breaker that
by-passes the MV UPS system and connect the grid directly to the load. This breaker is au-
tomatically controlled by the MV UPS.
PCM
Power Conditioning Mode. When operating on this mode, the MV UPS continuously condi-
tions the load voltage.
IM
Independent Mode. When operating on this mode, the MV UPS disconnects from the grid
by opening the input circuit breaker and supplies the load through the energy storage.
Bypass mode
The term is used to describe the system in bypass (not operating). When working in by-
pass mode, the bypass breaker is closed, and the input/output breakers are opened.
MC
Main Controller. Universal controller located in the PE120-1 enclosure.
UC
Universal Controller.
HUB
Two HUB controllers are located in PE120-2 and PE120-3 cabinets respectively. The main
function is to transfer the information to the main controller.