Communication
40
ABB Drives Profile - Enhanced
The ABB Drives Profile - Enhanced communication profile
provides register mapped access to the Control, Status,
Reference and Actual values of the ABB Drives Profile. The
mapping of the registers has been enhanced to allow writing of
Control and reading of Status in a single Read/Write Multiple
Register request.
Note:
If 32-bit parameters are mapped to DATA IN or DATA OUT,
adjust the length of the request message to fit both words of the
parameter.
Register Address*, **
Register Data (16-bit)
400001
ABB Drives Profile Control
400002
ABB Drives Profile Reference 1
400003
ABB Drives Profile Reference 2
400004
DATA OUT 1
400005
DATA OUT 2
400006
DATA OUT 3
400007
DATA OUT 4
400008
DATA OUT 5
400009
DATA OUT 6
400010
DATA OUT 7
400011
DATA OUT 8
400012
DATA OUT 9
400013
DATA OUT 10
400014
DATA OUT 11
400015
DATA OUT 12
400051
ABB Drives Profile Status
400052
ABB Drive Profile Actual 1
400053
ABB Drive Profile Actual 2
400054
DATA IN 1
400055
DATA IN 2
400056
DATA IN 3
400057
DATA IN 4
400058
DATA IN 5
400059
DATA IN 6
Содержание FSCA-01
Страница 1: ...ABB Drives Modbus Protocol Manual RS 485 Adapter Module FSCA 01...
Страница 2: ......
Страница 4: ......
Страница 6: ...Safety instructions 6...
Страница 22: ...Drive configuration 22...
Страница 24: ...Master configuration 24...
Страница 46: ...Communication 46...
Страница 50: ...Definitions 50...
Страница 51: ......