![ABB FAM3200 Series Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/abb/fam3200-series/fam3200-series_manual_3725316015.webp)
FAM3200
ARMORED VARIABLE AREA PURGEMETER | CI/FAM3200-EN REV. D
15
Model FAM3225 / FAM3255, conical float and orifice
The data listed applies to water at 20 °C (68 °F), 1 kg/dm
3
(62.43 lb/ft
3
),1 mPas (1 cP) and to air at 0 °C (32 °F), 1013 mbar (14.7 psia).
To set up devices for different measurement media or operating conditions please check the ABB Product Selection Assistant,
available at www.abb.com/flow.
Process connection
1
Maximum flowrate
V
std
2
(mPas [cp])
P
dif
3
(bar [psi])
P
sta
4
(bar [psi])
D
p
5
(mbar [psi])
Order code
6
Water
(l/h [USgal/h])
Air
(l/h [scfh])
⅜
in or ½ in
100 (26.42)
3200 (113.01)
8 (8)
4.0 (58.02)
0.3 (4.35)
60 (0.87)
20H
160 (42.27)
5000 (176.57)
8 (8)
4.0 (58.02)
0.3 (4.35)
70 (1.02)
21H
200 (52.83)
6000 (211.89)
8 (8)
4.0 (58.02)
0.3 (4.35)
80 (1.16)
22H
250 (66.04)
8000 (282.52)
8 (8)
4.0 (58.02)
0.3 (4.35)
90 (1.31)
23H
300 79.25)
9000 (317.83)
8 (8)
4.0 (58.02)
0.3 (4.35)
160 (2.32)
24H
½ in
400 (105.67)
12000 (423.78)
8 (8)
4.0 (58.02)
0.3 (4.35)
75 (1.09)
30H
500 (132.09)
15000 (529.72)
8 (8)
4.0 (58.02)
0.3 (4.35)
85 (1.23)
31H
600 (158.5)
18000 (635.66)
8 (8)
4.0 (58.02)
0.3 (4.35)
95 (1.38)
32H
700 (184.92)
21000 (5547.61)
8 (8)
4.0 (58.02)
0.3 (4.35)
105 (1.53)
33H
800 (211.34)
24000 (847.55)
8 (8)
4.0 (58.02)
0.3 (4.35)
130 (1.89)
34H
1 in
800 (211.34)
23800 (840.49)
3 (3)
16 (232.06)
0.4 (5.8)
60 (0.87)
40H
1000 (264.17)
29700 (1048.85)
3 (3)
16 (232.06)
0.4 (5.8)
62 (0.9)
41H
1600 (422.68)
47600 (1680.98)
3 (3)
16 (232.06)
0.4 (5.8)
74 (1.07)
42H
2000 (528.34)
59500 (2101.22)
3 (3)
16 (232.06)
0.4 (5.8)
85 (1.23)
43H
2500 (660.43)
74400 (2627.41)
3 (3)
16 (232.06)
0.4 (5.8)
105 (1.52)
44H
3000 (792.52)
89300 (3153.6)
3 (3)
16 (232.06)
0.4 (5.8)
130 (1.89)
45H
1 Connection nominal diameter
2 V
std
: Maximum permissible viscosity without calibration.
3 P
sta
: Minimum required static pressure to prevent compression oscillations. At low pressure, the use of the float damper is required.
4 P
min
: Minimum required static pressure in the device when using the optional float damper (Wendel).
5 Total pressure loss with stainless steel float at maximum flow.
6 Order code of the meter tube-float combination. See Ordering information in the data sheet for further information.
Ordering information in the data sheet