ARMORED VARIABLE AREA PURGEMETER | CI/FAM3200-EN REV. D
… 10 Specification
Measuring range table
Models FAM3220 / FAM3250 / FAM3225 / FAM3255, variable area and metal cone
The data listed applies for water at 20 °C (68 °F), 1 kg/dm
3
(62.43 lb/ft
3
), 1 mPas (1 cP) and for air at 0 °C (32 °F), 1013 mbar (14.7 psia).
To set up devices for different measurement media or operating conditions please check the ABB Product Selection Assistant,
available at www.abb.com/flow.
Process connection
1
Maximum flowrate
V
std
2
(mPas [cp])
P
dif
3
(bar [psi])
P
sta
4
(bar [psi])
D
p
5
(mbar [psi])
Order code
6
Water
(l/h [USgal/h])
Air
(l/h [scfh])
¼ in
1 (0.26)
35 (1.24)
4 (4)
0.7 (10.15)
1.0 (14.5)
8 (0.12)
01H
1.6 (0.42)
54 (1.91)
4 (4)
0.7 (10.15)
1.0 (14.5)
8 (0.12)
02H
2.5 (0.66)
100 (3.53)
6 (6)
0.7 (10.15)
1.0 (14.5)
8 (0.12)
03H
4 (1.06)
160 (5.65)
6 (6)
0.7 (10.15)
1.0 (14.5)
8 (0.12)
04H
6 (1.59)
230 (8.12)
18 (18)
0.7 (10.15)
1.0 (14.5)
8 (0.12)
05H
10 (2.64)
350 (12.36)
18 (18)
0.7 (10.15)
1.0 (14.5)
8 (0.12)
06H
16 (4.23)
540 (19.07)
18 (18)
0.7 (10.15)
1.0 (14.5)
8 (0.12)
07H
25 (6.6)
850 (30.02)
18 (18)
0.7 (10.15)
1.0 (14.5)
9 (0.13)
08H
40 (10.57)
1250 (44.14)
18 (18)
0.7 (10.15)
1.0 (14.5)
10.5 (0.15)
09H
60 (15.85)
1900 (67.1)
18 (18)
0.7 (10.15)
1.0 (14.5)
12.5 (0.18)
10H
100 (26.42)
3100 (109.48)
12 (12)
–
7
1.0 (14.5)
17.0 (0.25)
11H
1 Connection nominal diameter
2 V
std
: Maximum permissible viscosity without calibration.
3 P
dif
: Minimum required differential pressure for operation with a differential pressure regulator (FAM3220 / FAM3250 only).
4 P
sta
: Minimum required static pressure to prevent compression oscillations. For lower pressures, consult ABB.
5 Total pressure loss with stainless steel float at maximum flow.
6 Order code of the meter tube-float combination. See Ordering information in the data sheet for further information.