You can hard secure the local authorization of Remote Access by wiring a digital
input and output connected to the service box with the following options:
•
One input for authorization:
-
ON: Indicates that the Remote Access is authorized locally.
-
OFF: Indicates that the Remote Access is not authorized locally.
•
One output for status:
-
OFF: Indicates that the Service Box is starting or rebooting.
-
ON light is stable: Service Box is on Connected Services mode.
-
ON/OFF blinking: Service Box is in Remote Access mode (blinking ON
or OFF every second).
The DI/DO information are visible on the led in front of the Service Box and is
named T2M for DO and KEY for DI.
en1600001502
Continues on next page
118
Product manual - Connected Services
3HAC060439-001 Revision: E
© Copyright 2019 ABB. All rights reserved.
7 Remote Access
7.4 Customer site configuration
Continued