4 Mechanical Installation
IM/C1300 Rev. J
63
4.2.2 Panel Mounting
Fig. 4.5 Panel Mounting
Locate instrument
in cut-out
Secure in panel using
four bolts, nuts and washers
Drill four suitable holes
Optional gasket
(see
Note 2
below)
4
5
3
Dimensions in inches (mm)
Cut hole in panel
(see
Note 1
below)
Mark four mounting holes
12.72 (323.08)
minimum
11.25
(285.8)
14.00 (355.6)
14.19
(360.4)
0.64 (16.25)
1.70
(43.2)
4 holes 0.281 dia.
or tap for
1
/
4
in.
thread
2
12.72
(323.1)
minimum
1
13.7 (348.0)
maximum
0.15 (3.8)
minimum
0.20
(5.0)
0.15 (3.8)
minimum
14.6
(371.0)
maximum
Ensure cut-out positioned centrally
between mounting holes
Minimum Cut-out Dimensions
Maximum Cut-out Dimensions
Notes.
1. The recorder can be inserted into a panel cut-out of
any size between the minimum and maximum
dimensions illustrated, provided the cut-out is
positioned centrally relative to the fixing holes. If the
panel cut-out is larger than the maximum, a locally
manufactured adaptor plate is required.
2. If panel-mounting to NEMA 4X hosedown standard is
required, a continuous bead of suitable silicon sealant
must
be applied between the case flange and the
panel.
Do not
use the optional gasket.