![ABB AquaProbe 2 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/abb/aquaprobe-2/aquaprobe-2_installation-manual_4333014.webp)
Insertion-Type Electromagnetic Probe Flowmeter
AquaProbe 2
2 Mechanical Installation
12
IM/AP
Issue 9
2.5 Installing the AquaProbe
Warning.
When inserting or removing the AquaProbe suitable restraining equipment must be used to
prevent the probe being forced out under pressure. Ensure that the valve is fully open.
Fig. 2.10 Insertion Bore Clearance
Fig. 2.11 Installing the AquaProbe
25mm (1in) Minimum
Clearance
Apply
PTFE Tape
Remove
Cap
Tighten
(hand tight only)
Insert Probe
Into Valve
Tighten
Firmly
1
3
4
5
2