5 Installation
General information
The following points must be observed during installation:
• Secure the insertion sensor against pipe vibration.
• Insertion sensors must be installed without mechanical
tension (torsion, bending).
• Ensure temperature limits are not exceeded when
operating the insertion sensor.
• Avoid vacuum shocks in the piping to prevent damage to
the insertion sensor. Vacuum shocks can destroy the
insertion sensor.
• Do not remove the sealing plugs in the cable glands until
you are ready to install the electrical cable.
• The transmitter with a remote mount design must be
installed at a largely vibration-free location.
• When installing the transmitter in a control cabinet, ensure
adequate cooling is provided.
Pre-installation requirements
• Before installing a remote insertion sensor, check the cable is
of sufficient length for application/site conditions.
• Use only a single cable length. If the cable is not of sufficient
length do not extend it; replace it with new cable of sufficient
length and pot the terminal housing at the insertion sensor
end as detailed on page 16.
Installation
requirements
CAUTION
• The installation conditions shown must be
observed to achieve the best operational results.
• Care must be taken when unpacking and lifting
the insertion sensor.
Fluid level
The insertion sensor pipe must always be completely full.
Figure 4 Fluid level in pipe
Extremes of temperature
Do not install the insertion sensor in a position that will expose
it to extremes of temperature (for example, direct sunlight,
frost and snow). Provide appropriate weather protection where
necessary.