Safety standards

This product has been designed to satisfy the requirements of 
IEC61010-1:2010 3rd edition ‘Safety Requirements for Electrical 
Equipment for Measurement, Control and Laboratory Use’ and 
complies with US NEC 500, NIST and OSHA. 

This equipment complies with the requirements of CEI/IEC 
61010-1:2010 ‘Safety Requirements for Electrical Equipment for 
Measurement, Control and Laboratory Use’ and complies with 
US NEC 500 and Occupational Safety & Health Administration. 
If the equipment is used in a manner NOT specified by the 
Company, the protection provided by the equipment may be 
impaired.

Waste Electrical and Electronic Equipment 

(WEEE)

WEEE EU Directive 2012/19/EU covers disposal and recycling of 
electronic equipment at the end of life for reasons of 
environmental protection. 

   

For industrial installations, portable equipment is 
included. This means that when the AquaMaster4 
transmitter is used with a portable insertion sensor, 
it is included in directive’s scope and has the WEEE 
symbol (left) on its data label. Therefore, at the end of 
life, contact the supplier for specialist waste 
recycling. It must not be disposed of as municipal 
waste.

Permanent Industrial installations are not designated within 
this directive for recycling. At the point of supply the intended 
use is not always known, so the WEEE symbol is included on all 
remote forms of the AquaMaster4 transmitter.

Product recycling and disposal (Europe only)

   

Electrical equipment marked with this symbol may 
not be disposed of in European public disposal 
systems after 12 August 2005. To conform to 
European local and national regulations (EU Directive 
2012/19/EU), European electrical equipment users 
can now return old or end-of-life equipment to the 
manufacturer for disposal at no charge to the user. 
ABB is committed to ensuring that the risk of any 
environmental damage or pollution caused by any of 
its products is minimized as far as possible.

     

  IMPORTANT (NOTE)   

 

For return for recycling, please contact the equipment 
manufacturer or supplier for instructions on how to 
return end-of-life equipment for proper disposal.

Information on ROHS Directive 2011/65/EU 

(RoHS II)

ABB, Industrial Automation, Measurement & Analytics, UK, fully 
supports the objectives of the ROHS II directive. All in-scope 
products placed on the market by IAMA UK on and following the 
22nd of July 2017 and without any specific exemption, will be 
compliant to the ROHS II directive, 2011/65/EU.

Product symbols

Symbols that may appear on this product are shown below:

 

  Risk of electric shock.

 

  This symbol, when noted on a product, indicates a 

potential hazard which could cause serious personal 
injury and/or death. The user should reference this 
instruction manual for operation and/or safety 
information. 

 

  Protective earth (ground) terminal.

 

  Functional earth (ground) terminal.

 

  Direct current supply only.

 

  Alternating current supply only.

 

  This symbol, when noted on a product enclosure or 

barrier, indicates that a risk of electrical shock and/or 
electrocution exists and indicates that only 
individuals qualified to work with hazardous voltages 
should open the enclosure or remove the barrier.

 

  Recycle separately from general waste under the 

WEEE directive.

Содержание AquaMaster4

Страница 1: ...Master4 is a range of high performance electromagnetic flowmeters for the measurement of electrically conductive fluids and are normally supplied as factory configured calibrated systems This Operatin...

Страница 2: ...ments 9 Installation requirements 9 Fluid level 9 Extremes of temperature 9 Seal materials fluid temperatures 10 Pipeline forces torque 10 Spillage onto the insertion sensor 10 Flow direction 10 Envir...

Страница 3: ...4 11 Recycling and disposal 24 Disassembly 24 Disposal 24 12 Specification 25 13 Appendix 26 Declarations of conformity 26 Torque information 26 International Standard for flow measurement 26 Velocity...

Страница 4: ...ard reverse and net and pressure option of a conductive fluid The insertion sensor has been designed for use exclusively within the technical limit values indicated on the identification plate and in...

Страница 5: ...marked with this symbol may not be disposed of in European public disposal systems after 12 August 2005 To conform to European local and national regulations EU Directive 2012 19 EU European electrica...

Страница 6: ...insertion sensor Terminal box Alignment handle Insertion sensor valve Safety mechanism must be engaged see page 16 Locking collar Process connection 1 in BSP 1 5 in BSP 1 in NPT Locknut Label see page...

Страница 7: ...ngress protection rating G Insertion sensor length H Insertion sensor disposal categories I Applicable certification Figure 2 Name plate integral insertion sensor example Remote insertion sensor 500 M...

Страница 8: ...ue to suspended loads In the case of suspended loads a danger of the load falling exists Remaining under suspended loads is prohibited Storing the insertion sensor Bear the following points in mind wh...

Страница 9: ...nsure adequate cooling is provided Pre installation requirements Before installing a remote insertion sensor check the cable is of sufficient length for application site conditions Use only a single c...

Страница 10: ...e the insertion sensor Figure 8 Spillage Flow direction The insertion sensor can be installed in one of two positions in the pipe On the center line or At the mean axial velocity point 1 8 pipe diamet...

Страница 11: ...15 and 65 ft lengths Renewable energy cable is available as a 10 m 30 ft length Localized heating welding The insertion sensor must not be submitted to localized heating during installation remember t...

Страница 12: ...0 300 500 700 or 1000 11 8 19 7 27 6 or 39 4 maximum insertion depth 800 1000 1200 or 1400 31 5 39 4 47 3 or 55 0 Thread 1 in BSP 1 5 in BSP 1 in NPT 320 12 6 113 4 5 103 4 1 M20 Cable gland shown Rem...

Страница 13: ...1 38 D Example for a pipe of internal diameter 593 mm 23 35 in F 0 861 derived from Figure 14 Fi 1 1 38 593 Fi 1 021 Pipe bore in mm Pipe bore in inches Profile factor F p 200 400 600 800 1000 1200 1...

Страница 14: ...extra source of errors ABB supply an internal pipe measuring insertion sensor pipe bore gauging tool for this purpose see Figure 15 The tool is used as follows 1 Fit the tool into the back of the valv...

Страница 15: ...on Category II of IEC 61010 All equipment connected to the transmitter s terminals must comply with local safety standards IEC 60950 IEC61010 1 Grounding IMPORTANT NOTE Only to be installed in metalli...

Страница 16: ...let potting material enter conduit if used Figure 18 Potting the remote insertion sensor terminal housing Pipeline preparation CAUTION Prepare the main or pipeline into which this insertion sensor is...

Страница 17: ...e fitted and engaged to prevent the insertion sensor being forced out under pressure Ensure the valve is fully open Suitable valve pre fitted to process Valve open close handle 25 mm 1 in Minimum clea...

Страница 18: ...rring to Figure 22 1 Measure internal diameter D of the pipe see page 14 2 Open valve A fully with valve lever B 3 Slacken nut C 4 Lower insertion sensor D into valve A 5 Slide positioning collar E do...

Страница 19: ...pipe to the top of the valve plate VP item A 3 Slacken nut B 4 Lower insertion sensor C until it touches valve plate D 5 Slide positioning collar E down to nut B and lock in place using a 4 mm hexagon...

Страница 20: ...he top of the pipe to the top of the valve plate VP item A 3 Slacken nut B 4 Lower insertion sensor C until it touches valve plate D 5 Slide positioning collar E down to nut B and lock in place using...

Страница 21: ...m see page 16 must be fitted and engaged to prevent the insertion sensor being forced out under pressure Ensure the valve is fully open Safety restraint omitted for clarity Referring to Figure 25 1 Sl...

Страница 22: ...st be checked before commissioning the insertion sensor The wiring must have been completed as described in the Installation section on page 15 The insertion sensor must be grounded correctly The ambi...

Страница 23: ...the insertion sensor is a precision built part of the equipment and must be handled with care When the insertion sensor is not in use fully retract the tip of the insertion sensor and replace the end...

Страница 24: ...00L1200 FEW4 ball valve stainless steel 11 2 in BSP 3KXF221400L1300 FEW4 bush stainless steel 11 2 in M x 1 BSP 3KXF221400L1400 FEW4 ball valve stainless steel 11 2 in NPT 3KXF221400L1500 FEW4 bush st...

Страница 25: ...32 to 140 F Conductivity 50 S cm Metrological performance and certifications Accuracy 2 of rate or 2 mm s 0 08 in s whichever is the greater Volume Refer to ISO 7145 1982 BS 1042 section 2 2 for deta...

Страница 26: ...the validating conditions can be met the method described on page 10 is the most practical It is possible to measure the velocity either on the center line which reduces sensitivity to positional err...

Страница 27: ...length is 650 mm 26 in Max velocity at 650 mm is 3 6 m s Velocity profiles background Figure 28 shows a fully developed turbulent profile of the flow within a pipe Such diagrams illustrate the distri...

Страница 28: ...reviously this process gives us the wrong answer Fortunately there is a mathematical relationship between the velocity at the center line and the mean velocity within the pipe the Profile Factor F The...

Страница 29: ...ing boss directly opposite the one already fitted IMPORTANT NOTE Due to software configuration all calculations are in metric units Therefore if using an imperial pipe the diameter MUST be converted i...

Страница 30: ...UAMASTER4 ELECTROMAGNETIC FLOWMETER INSERTION SENSOR OI FEW400 AP EN REV B Acknowledgments MODBUS is a registered trademark of the Modbus IDA organization Sensus is a registered trademark of Sensus US...

Страница 31: ...AQUAMASTER4 ELECTROMAGNETIC FLOWMETER INSERTION SENSOR OI FEW400 AP EN REV B 31 Notes...

Страница 32: ...Fax 86 0 21 6105 6677 Email china instrumentation cn abb com abb com measurement We reserve the right to make technical changes or modify the contents of this document without prior notice With regard...

Отзывы: