Electronic Commercial Water Meter
AquaMaster™
5 Specification
42
IM/AM
Issue 13
Wetted Materials
Screw end meters
Brass
Flanged meters
Electrodes – stainless steel 316L
Lining
Suitable for potable water (UKWFBS listed)
Pressure limitations
As flange rating
Conductivity
>50µS/cm
End Connections
Thread end connections
15mm – G
3
/
4
in. B
3
/
4
in. NPSM
20mm – G 1 in. B 1 in. NPSM
25mm – G 1
1
/
4
in. B 1
1
/
4
in. NPSM
40 to 300mm (1.5 to 12 in.) flanged
BS4504/ISO 7005 – PN16, PN10
ANSI B16.5 1.5 Class 150
AS 2129 Tables C, D and E
AS 4087/14, AS4087/16
JIS to BS2210, 5k, 10k and 30k
BS10 Tables D and E
350 to 600mm (14 to 24 in.) flanged
2-wire for inductive pads (max. cable length 80m)
3-wire for AMR
Compatible readers
BS4504/ISO 7005 – PN10, PN16
BS10 Table D & E
AS 2129 Tables D and E
AWWA C207 Class B and D
ANSI B16.5 1.5 Class 150 (
≤
24 in.)
AS4087/14, AS4087/16