Electronic Commercial Water Meter
AquaMaster™
4 Start-Up And Operation
IM/AM
Issue 13
33
4 Start-Up And Operation
4.1 Connecting Batteries
The AquaMaster is supplied with one or two batteries, but not connected. To connect see Fig. 4.1.
4.2 Start-up
Remove any plastic film from the AquaMaster light sensitive display window before commencing normal
operation.
When electrical power is connected, or the plastic film is removed from the display window with electrical
power connected, the AquaMaster performs a self-test operation. If successful, 'Pass' is indicated in the
display window.
If the display shows 'Err 1', check the sensor wiring. If the fault is rectified, the transmitter restarts
automatically.
If the display shows 'Err 2 or 3', contact ABB.
Warning.
The battery used in this device may present a risk of fire or chemical burns if mistreated. Do not
recharge, disassemble, heat above 100°C or incinerate.
Replace battery pack with an ABB supplied part only. Use of another battery may present a risk of
fire or explosion.
Dispose of all battery packs promptly. Keep away from children.
Dispose of battery packs in accordance with local regulations.
Where possible, recycle used batteries.
Contact the local environmental authority for further information regarding disposal or recycling
schemes for used batteries.
Note.
Each battery must be connected to the cable from the same side of the termination area as the
battery position.
Note.
GSM-equipped transmitters are supplied with the batteries connected but in transportation mode
– refer to the label attached to the equipment.