Electronic Commercial Water Meter
AquaMaster™
3 Electrical Installation
22
IM/AM
Issue 13
Fig. 3.13 Transmitter Connections (Glands/Conduit Entry)
Caution.
(Remote versions)
Remove foil screens completely, and plastic/foil screens and any fillers
Twist the three screen wires together and sleeve them.
Keep cable pairs twisted.
Make connections only as shown.
Maintain Environmental Protection at all times.
Conduit connections must provide cable entry sealing.
Fig. 3.14 Sensor Cable Connections (Gland/Conduit, Remote version)
Caution.
With Belden Cable 8777, ensure that the black wires are not interchanged and remain with the
associated twisted pair.
1
7
1 Brown(BN)
2 Red (RD)
3 Orange (OR)
4 Yellow (YL)
5 Sleeved Ground
6 Blue (BL)
7 Violet (VI)
ABB
Belden 8777
CABLE
1 Black
2 Green
3 Black
4 Red
5 Sleeved Ground
6 Black
7 White