MoTor InsTAllATIon
19
4.5. Electrical installation
Warning – High Voltage
Touching a live motor connection causes serious injuries or death.
The motor needs an inverter to operate. The inverter must be able to supply 3 phase AC current and be
capable of controlling the motor. The motor has been tested and optimized together with the ABB
HES880 inverter. An inverter with a different control strategy, switching frequency and pulse pattern
might have an impact on the motor performance. For more information about the HES880 inverter,
please contact your local ABB sales office.
The motor is equipped with connectors. Types and quantities of the connectors is depending on
applicable options of the motor. Figure 9 shows an overview of the electrical connection interfaces and
additional details in Table 5. Please see circuit diagram 3BSM625000-10 for full details.
Figure 9.
Motor electrical connection interfaces.
Connector description
Type of connector
Comment
Temperature sensor
M12 male, 4-pole, B-coded
Temperature sensor (spare)
M12 male, 4-pole, B-coded
Heater
M12 male, 2-pole, B-coded
Optional variant code
Resolver
M12 male, 8-pole, A-coded
VC450 or VC451
High Voltage Interlock Loop (HVIL)
M12 male, 4-pole, B-coded
Optional variant code VC848
Power connectors (3x), phase U
PLOOU-301-90M8
Power connectors (3x), phase V
PLOOV-301-90M8
Power connectors (3x), phase W
PLOOX-301-90M8
Earth point
Threaded hole M12, depth 18
Table 4.
Electrical connectors.