MoTor InsTAllATIon
21
Typical way of connecting the mating power connectors is as following.
1.
Open its latch by pushing the color-coded plastic part forward and down
2.
Gently push it into the connector on the terminal box
3.
Close the latch
4.
See supplier instructions for further details.
Figure 11. Connecting the mating power connectors to the motor.
NOTE: The mating power connectors are also available as an over-molded option.
NOTE: Ensure that all cable connections are installed in an appropriate way and are suitable for high
frequency currents.
4.5.2. Earth point
A dedicated earth point is located on the motor, see Figure 9.
The earth cable from the inverter or vehicle chassis must be installed in an appropriate way and be
suitable for high frequency currents.
NOTE: Ensure that the dedicated surface on the earth point is free from paint and dirt to ensure a
good connection
4.5.3. Auxiliary connection
The motor is equipped with a number of auxiliary M12 connectors. Number and type as per applied
options to the motor. See Figure 12 for positions of the connectors and Table 5. Please see circuit
diagram 3BSM625000-10 for full details of type and pin configurations.
NOTE: Ensure that M12 connectors are connected with a mating connector or with the M12
protection caps. Otherwise, the motor IP class will be compromised.
NOTE: Ensure that the protection class of the selected mating low voltage connector is equal to or
better than the motor protection class.
Figure 12. Auxiliary connectors, motor seen from N-end.