10.11
Cable management system specifications
A
A
Y
X
A
Clamp
X
Distance from the cable exit point
Y
Distance from the connector
Cable type
(A)
Length
Clamp
model
Distance
from the
cable exit
point (X)
Distance
from the
connector
(Y)
Counter-
weights
[m]
[ft]
CCS-1
200A
4
13
BP-1394-2
64A
50 %
50 %
3
CCS-1
200A
6
20
BP-1394-2
64A
30 %
70 %
4
CCS-1
200A
8
26
BP-1394-2
64A
See *
CCS-1
400A
4
13
BP-1394-2
82A
50 %
50 %
4
CCS-1
400A
6
20
BP-1394-2
82A
30 %
70 %
5
CCS-1
400A
8
26
BP-1394-2
82A
See *
CHAdeMO
200 A
4
13
BP-1394-3
55A
50 %
50 %
5
CHAdeMO
200 A
6
20
BP-1394-3
55A
30 %
70 %
5
CHAdeMO
200 A
8
26
BP-1394-3
55A
See *
* The maximum cable length supported by the ABB cable retraction system is 6
m (20 ft). If the EVSE is equipped with a cable longer than 8 m (26 ft) the EVSE
is not compliant with NEC 625.17. An external cable management system must be
installed to comply with the standard.
Technical data
9AKK108466A3703-EN | 001
79