Technical data
79
Ambient conditions
Environmental limits for the drive are given below. The drive is to be used in a heated,
indoor, controlled environment.
Operation
installed for stationary use
Storage
in the protective package
Transportation
in the protective package
Installation site altitude
0 to 4000 m (6600 ft) above
sea level. [See also section
on page
.]
-
-
Air temperature
-10 to +55°C (14 to 131°F).
No frost allowed. See section
on page
-40 to +70°C (-40 to +158°F) -40 to +70°C (-40 to +158°F)
Relative humidity
0 to 95%
Max. 95%
Max. 95%
No condensation allowed. Maximum allowed relative humidity is 60% in the presence of
corrosive gases.
Contamination levels
(IEC 60721-3-3,
IEC 60721-3-2,
IEC 60721-3-1)
No conductive dust allowed.
According to IEC 60721-3-3:
Chemical gases: Class 3C2
Solid particles: Class 3S2
The drive must be installed in
clean air according to
enclosure classification.
Cooling air must be clean,
free from corrosive materials
and electrically conductive
dust.
According to IEC 60721-3-1:
Chemical cases: Class 1C2
Solid particles: Class 1S2
According to IEC 60721-3-2:
Chemical cases: Class 2C2
Solid particles: Class 2S2
Sinusoidal vibration
(IEC 60721-3-3)
Tested according to
IEC 60721-3-3, mechanical
conditions: Class 3M4
2…9 Hz: 3.0 mm (0.12”)
9…200 Hz: 10 m/s
2
(33 ft/s
2
)
–
–
Shock
(IEC 60068-2-27, ISTA 1A)
–
According to ISTA 1A.
Max. 100 m/s
2
(330 ft/s
2
),
11 ms
According to ISTA 1A.
Max. 100 m/s
2
(330 ft/s
2
),
11 ms
Free fall
Not allowed
76 cm (30”)
76 cm (30”)
Materials
Drive enclosure
• PC/ABS, colour NCS 1502-Y (RAL 9002 / PMS 420 C)
• hot-dip zinc coated steel sheet
• extruded aluminium AlSi.
Packaging
Corrugated cardboard, PP bands.
Disposal
The drive contains raw materials that should be recycled to preserve energy and natural
resources. The package materials are environmentally compatible and recyclable. All
metal parts can be recycled. The plastic parts can either be recycled or burned under
controlled circumstances, according to local regulations. Most recyclable parts are marked
with recycling marks.
If recycling is not feasible, all parts excluding electrolytic capacitors and printed circuit
boards can be landfilled. The DC capacitors contain electrolyte, which is classified as
hazardous waste within the EU. They must be removed and handled according to local
regulations.
For further information on environmental aspects and more detailed recycling instructions,
please contact your local ABB distributor.
Содержание ACSM1 Series
Страница 1: ...ACSM1 Hardware Manual ACSM1 04 Drive Modules 0 75 to 45 kW...
Страница 2: ......
Страница 4: ......
Страница 14: ...Table of contents 14...
Страница 20: ...About this manual 20...
Страница 24: ...The ACSM1 04 24...
Страница 30: ...Planning the cabinet assembly 30...
Страница 46: ...Planning the electrical installation 46...
Страница 70: ...Maintenance 70...
Страница 84: ...Technical data 84...
Страница 90: ...Mains filters 90...
Страница 96: ...Dimension drawings 96 Frame size A...
Страница 97: ...Dimension drawings 97...
Страница 98: ...Dimension drawings 98 Frame size B...
Страница 99: ...Dimension drawings 99...
Страница 100: ...Dimension drawings 100 Frame size C air cooled module...
Страница 101: ...Dimension drawings 101...
Страница 102: ...Dimension drawings 102 Frame size C for cold plate mounting...
Страница 103: ...Dimension drawings 103 Frame size D air cooled module...
Страница 104: ...Dimension drawings 104 Frame size D for cold plate mounting...
Страница 106: ...Dimension drawings 106 Mains filters type JFI xx...
Страница 108: ...Dimension drawings 108 Braking resistors type JBR xx...
Страница 110: ...Dimension drawings 110...
Страница 111: ......