370 Parameters
(This parameter is only effective when the drive is the master
on a D2D link. See parameters
.)
specify the followers
whose status word is monitored by the master.
This parameter selects the followers (out of followers 1…16)
whose status words are monitored by the master.
If a follower reports a fault (bit 3 of the status word is on), the
action specified in
is taken. Bits 0
and 1 of the status word (ready states) are handled as defined
by
Using
, it is possible to define whether any given
follower is only monitored when it is stopped.
Note:
Also activate communication supervision for the same
The status of communication is shown by
and
-
0000h…FFFFh
D2D follower status supervision selection (followers 1…16).
1 = 1
Selects the followers (out of followers 17…32) whose status
words are monitored by the D2D master.
Note:
Also activate communication supervision for the same
See parameter
.
-
0000h…FFFFh
D2D follower status supervision selection (followers 17…32).
1 = 1
No.
Name/Value
Description
Def
/
FbEq16
Bit
Name
Description
0
Follower 1
1 = Status of follower 1 is monitored.
1
Follower 2
1 = Status of follower 2 is monitored.
…
…
…
15
Follower 16
1 = Status of follower 16 is monitored.
Bit
Name
Description
0
Follower 17
1 = Status of follower 17 is monitored.
1
Follower 18
1 = Status of follower 18 is monitored.
…
…
…
15
Follower 32
1 = Status of follower 32 is monitored.
Содержание ACS880-x04
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Страница 4: ......
Страница 18: ...18 Using the control panel ...
Страница 24: ...24 Control locations and operating modes ...
Страница 111: ...Application macros 111 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 112: ...112 Application macros ...
Страница 496: ...496 Additional parameter data ...
Страница 544: ...544 Fault tracing ...
Страница 602: ...602 Control chain diagrams ...