ACS 160 User’s Manual
103
8207
TARGET 1 LO
8208
TARGET 1 HI
Target position 1 reference values. See example on page 100.
8209
TARGET 2 LO
8210
TARGET 2 HI
Target position 2 reference values. See example on page 100.
8213
POS DELAY
Stop delay scaling factor at positioning mode 9. Stop time at turning points can be scaled with this
parameter. If the parameter value is zero, then the delay is always zero.
Delay [ms] =
POS
DELAY
* 40 / Positioning frequency reference (Hz).
8215
POS MODE
Positioning mode selection.
4 =
RELAT
MOVE
1
Selected target position is relative to previous target position. When start command is given, the position
counter is first reset to zero and then corrected with the distance between actual and desired stopping
position. The purpose of this is to prevent the axis to “creep” from its original home position. Correction is
only made, when the previous move has reached the target window area. If two targets are used, make sure
that target reference is changed only at stop-state!
5 =
ABS
MOVE
1
Selected target position is absolute. Position counter is not reset when start command is given. This mode is
typically used when the load is moved between two positions.
6 = A
BS
MOVE
CC
1
Basic operation as in mode 5. Cyclic correction added. Positioning counter is set to the value of home
position parameters 8225
HOME
POS
LO
and 8226
HOME
POS
HI
, when digital input 3 (DI3) state changes from
inactive to active state.
7 = A
BS
MOVE
CC
2
Basic operation as in mode 5. Cyclic correction added. Positioning counter is set to the value of home
position parameters 8225
HOME
POS
LO
and 8226
HOME
POS
HI
, when digital input 3 (DI3) state changes from
active to inactive state.
8 =
RELAT
MOVE
2
Same as mode 4, except that the position counter starts counting from the value set with parameters 8225
HOME
POS
LO
and 8226
HOME
POS
HI
every time when Start command is given. This position mode provides
no position correction possibilities.
9 =
CONT
MOVE
1
Selected target is absolute. Continuous move between home and target1 position. Used for example for
spinning wires. A position time delay parameter 8213
POS
DELAY
and external frequency reference
parameter 8217
AUX
POS
CMD
can be defined.
Code Description
Содержание ACS 160
Страница 2: ......
Страница 4: ......
Страница 10: ...viii ACS 160 User s Manual ...
Страница 12: ...2 ACS 160 User s Manual ...
Страница 32: ...22 ACS 160 User s Manual ...
Страница 42: ...32 ACS 160 User s Manual ...
Страница 56: ...46 ACS 160 User s Manual ...
Страница 116: ...106 ACS 160 User s Manual ...
Страница 122: ...112 ACS 160 User s Manual ...
Страница 126: ...116 ACS 160 User s Manual ...
Страница 136: ...126 ACS 160 User s Manual ...
Страница 137: ......