Multifamily house with 6 private apartments
» System type: audio/video combined
» Wiring: rising mains with branch connections, i.e. video
distributors
» Devices used:
» One
ABB-
Wel
come
video outdoor station,
6gang, article number: 83122/6-xxx-500
» Four
ABB-
Wel
come
audio indoor stations with handset,
article number: 83205 AP-xxx-500
» Two
ABB-
Wel
come
Touch
,
article number: 83220 AP-xxx-500
»
ABB-
Wel
come
system controller,
article number: 83300-500
» Three
ABB-
Wel
come
video distributors, FM indoor,
article number: 83320/2 U-500
» Six floor call buttons
» One electric door opener
Commercial object
» System type: audio/video
» Wiring: looped from device to device
» Devices used
» One
ABB-
Wel
come
video outdoor station, 1gang,
article number: 83121/1-xxx-500
» One
ABB-
Wel
come
audio outdoor station, 1gang,
article number: 83101/1-xxx-500
» One
ABB-
Wel
come
audio indoor station with display,
article number: 83200 U, cover plates article number:
83260-xxx-500 2gang frame
» One
ABB-
Wel
come
Touch,
article number: 83220 AP-xxx-500
» One
ABB-
Wel
come
system controller,
article number: 83300-500
» One
ABB-
Wel
come
video outdoor distributor,
article number: 83325/2-500
» One
ABB-
Wel
come
bell transformer,
article number: 83315-500
» One switch actuator, door/light,
article number: 83330-500
» Two electric door openers
The combined audio/video solution for the multifamily house
with six private apartments. The wiring from the ABB-Welcome
system controller to the indoor stations is designed as rising
mains. From here the wires branch off into the apartments. Each
of the two bottom floors has an ABB-Welcome audio indoor sta-
tion with handset installed. All branch connections require video
distributors.
The combined audio/video solution for a building with several
entrances – such as private apartment and office. One indoor
station is located on the left at the office entrance, another one
on the right at the apartment. Inside the building the two internal
bus lines of the system controller are used. A distributor is
required to connect the two outdoor stations.
S
in
D
in
D
in
D
A
D
out
S
Fig. 3
Fig. 4
User Manual ABB-
Wel
come
| Examples for typical
ABB-
Wel
come
systems 13
Содержание 83300-500
Страница 1: ...Door Communication ABB Welcome User Manual ...
Страница 3: ...User Manual ABB Welcome 3 ...
Страница 4: ...4 User Manual ABB Welcome Most welcome Intelligence with system ...
Страница 8: ...8 User Manual ABB Welcome ...
Страница 15: ...User Manual ABB Welcome Planning ABB Welcome systems 15 ...
Страница 31: ...User Manual ABB Welcome Installation 31 ...
Страница 37: ...User Manual ABB Welcome Commissioning 37 ...
Страница 43: ...User Manual ABB Welcome Control 43 ...
Страница 45: ...User Manual ABB Welcome Overview of Range 45 ...
Страница 55: ...Notes ...
Страница 57: ......