Device
Setting
Note
ABB-Welcome outdoor station
Address of the outdoor station
Button sounds on/off
Assigning the doorbell buttons to
the apartments
Only if the specified allocation is different
ABB-Welcome indoor station
Address of the indoor station
Setting of the terminal resistor
Setting of the standard outdoor station
Only if several outdoor stations are used
in the one system
Setting of the main indoor station
ABB-Welcome system controller
Setting of the door opener times and light times
Only if the door opener and light switch
are used
ABB-Welcome video indoor distributor
Setting of the terminal resistor
ABB-Welcome Switch actuator, door/light
Address of the associated outdoor station
Setting of the door opener or light switch
Setting of the door opener times and light times
Assigning the doorbell push-button of an outdoor station
to an apartment
Factory assignment of the doorbell push-buttons
Fig. 25
The doorbell push-buttons of an outdoor station are assigned
to the apartments consecutively from top to bottom and left
to right with the addresses 01, 02, etc.
This assignment applies equally to several outdoor stations
in a system. This means that in Figure 26 in each outdoor
station push-button A is assigned to apartment 01, etc.
This factory setting is fixed via two potentiometers on the
rear of the outdoor station. "K10" must be set on "0" and
"K1" on "1".
Change in the assignment of the doorbell push-buttons
("Offset")
Fig. 27
The preset addresses of the doorbell push-buttons can be
changed. This means that the top doorbell push-button on
the left side is assigned to a different apartment. The other
doorbell push-buttons are consecutively assigned to the
other apartments.
Figure 27 shows the three outdoor stations from the example
on page 16. The outdoor station at the gate entrance and the
outdoor station at the left building show the factory assignment
of the doorbell push-buttons. At the outdoor station of the
building on the right an offset of 03 is set.
The value of the "Offset" is fixed at the rear of the outdoor
station. Here "K10" indicates the tens digit (here "0") and
"K1" the single digit (here "3"). The factory setting of the
offset is on "01".
Overview of the different setting options
38 Commissioning |
User Manual ABB-
Wel
come
Содержание 83300-500
Страница 1: ...Door Communication ABB Welcome User Manual ...
Страница 3: ...User Manual ABB Welcome 3 ...
Страница 4: ...4 User Manual ABB Welcome Most welcome Intelligence with system ...
Страница 8: ...8 User Manual ABB Welcome ...
Страница 15: ...User Manual ABB Welcome Planning ABB Welcome systems 15 ...
Страница 31: ...User Manual ABB Welcome Installation 31 ...
Страница 37: ...User Manual ABB Welcome Commissioning 37 ...
Страница 43: ...User Manual ABB Welcome Control 43 ...
Страница 45: ...User Manual ABB Welcome Overview of Range 45 ...
Страница 55: ...Notes ...
Страница 57: ......