COLOR COMPENSATION SEQUENCE PAGE 2.7
Reading = xx<units>
Abort color compensation = NO
D/F cnt to compensation = xx
D/F cnt to end of sequence = xx
SET UP INSTRUMENT PAGE 3.1
Software issue = x
Control temperature = xx.x‘C
Display units = <units>
Display units as = xxx
Alter setup security code = xxxx
SET UP INSTRUMENT PAGE 3.0
Enter security code xxxx
To
page 4
YES
NO
YES
mg/l
2.
68
Phosphate as PO
4
Page 0
DIAGNOSTIC INFORMATION PAGE 1.0
Next 5 weekly service = DD/MM
Next yearly service = DD/MM/YY
Monitor in service
SYSTEM INFORMATION PAGE 1.1
Optical system temperature = xx.x‘C
Reaction block temperature = xx.x‘C
Zero offset = xx.x<units>
Calibration factor = x.xx
Date (DD/MM/YY) = xx/xx/xx
Time (HH:MM:SS) = xx:xx:xx
SYSTEM INFORMATION PAGE 1.2
Time units (DD/MM/YY)
Next AUTO ZERO CAL = xx/xx/xx
Last AUTO ZERO CAL = xx/xx/xx
Next SEC CAL = xx/xx/xx
Last SEC CAL = xx/xx/xx
MAINTENANCE AND CALIBRATION. PAGE 2.0
Enter security code xxxx
ROUTINE MAINTENANCE. PAGE 2.1
5 Weekly pipe rinse = NO
5 Weekly solution replacement = NO
Annual service = NO
Default calibration parameters = NO
Alter maintenance security code = xxxx
ROUTIN UTO ZERO valve = NO
Energise SECONDARY CAL valve = NO
Energise EMERGENCY SAMPLE valve = NO
Switch lamp on continuous = NO
SET UP CALIBRATION. PAGE 2.3
Initiate manual AUTO ZERO = NO
SEC CAL solution value = xx<units>
Calibration date (DD/MM/YY) = xx/xx/xx
Calibration time (HH:MM) = xx:xx
AUTO ZERO frequency = xx
AUTO ZEROs between SEC. CALS = x
YES
SET UP COLOR COMPENSATION PAGE 3.3
Color comp frequency = xxx
Color comp applied = x<units>
Color comp date (DD/MM/YY) = xx/xx/xx
Color comp time (HH:MM:) = xx:xx
AUTO ZERO SEQUENCE PAGE 2.4
Reading = xxx<units>
Time to compensation = xx min
Abort AZ calibrations = NO
SECONDARY CAL = NO
SECONDARY CALIBRATION SEQUENCE PAGE 2.5
Reading = xxx<unit>
Time to compensation = xx min
Abort SEC calibrations = NO
SAMPLE RECOVERY SEQUENCE PAGE 2.6
Reading = xxx <units>
Time to end of sequence = xx min
Zero offset = xx.x <units>
Calibration factor = x.xx
YES
Note. Programming Page 2.7,
shown in the dashed box, is displayed
only if a timed color compensation is
attempted during an automatic
calibration sequence.
CLOCK SETUP. PAGE 3.2
Date (DD/MM/YY) = xx/xx/xx
Time (HH:MM) = xx:xx
WARINING: Adjusting any of the above
time parameters will alter the next
Auto Calibration Date.
6
SINGLE STREAM PROGRAMMING
In normal operation (Operating Pages 0 and 1) the display
gives indication of the units of measurement, diagnostics,
calibration information and time. Selection is made by means
of the
and
switches.
Operation of the
switch enables a series of 'programming'
pages to be displayed. Unauthorized entries to these pages
are inhibited by a four-digit security code which is displayed
immediately after the page header.
Values displayed in Operating Pages 0 and 1 are for viewing
only and cannot be altered by the operator. Displayed values
on subsequent pages indicated by x's can be altered by means
of the
and
switches. Options such as Yes/No or High/
Low are also selected using these switches. Passing onto the
next parameter, or exiting from the page, automatically enters
the new value into memory.
Programming information for users of multi-stream monitors is
contained in Appendix A.