![ABB Robotics FlexGripper Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/abb-robotics/flexgripper/flexgripper_product-manual_450831063.webp)
Position 3
Magnetic proximity switch
A
Replace magnetic proximity switches in position 1
Use this procedure to replace magnetic proximity switches of the claw cylinder.
DANGER
Turn off all electric power and pneumatic pressure supplies to the gripper!
Note
Action
Loosen the small screw and pull out the
magnetic proximity switch.
1
Parts: A: Small screw
See circuit diagram for details.
Open the terminal box and remove the
cable.
2
Remove the magnetic proximity switch.
3
Continues on next page