N. 

Ladder bracket. The ladder bracket is 
attached to the header and accepts the 
top of the provided extension ladder. 

O. 

Ladder straps. A ladder strap is located 
on each side of the ladder bracket to 
further secure the provided extension 
ladder. 

P. 

Pressure monitor mounting bracket. An 
Abatement Technologies’ RPM series 
pressure monitor can be installed inside 
the unit on this mounting bracket. This 
mounting bracket is included with all 
units (pressure monitor sold separately). 

Q. 

Remote variable speed control. There 
are designated electrical sockets on the 
inside and the outside of the unit that are 
wired to the remote variable speed 
control. Plugging a PAS750 Portable Air 
Scrubber into these sockets allows 
those units to be controlled with the 
remote variable speed knob that can be 
accessed while standing on the 
extension ladder. 

R. 

Internal GFCI receptacles. One 
receptacle is designated for a PAS750 
Portable Air Scrubber to allow remote 
variable speed control (Q). The 
remaining receptacles can be used for 
other devices that run off of 110-
120VAC. A maximum of 15 amps can be 
used with AG8000’s electrical system. 

S. 

PAS750 Portable Air Scrubber (not 
included). The optional PAS750 Portable 
Air Scrubber unit is recommended in 
order to create negative pressure for 
particulate containment. 

T. 

Recessed ladder pockets. There are two 
recessed pockets in the floor that secure 
the extension ladder’s feet to keep the 
ladder from sliding and also to ensure 
that the proper angle is kept. 

U. 

Top cover (not shown). The top cover 
closes the opening in the header to 
provide full containment during transport 
and during usage before ceiling tiles are 
removed (replacement P/N: 
AG8000TOP-FR). 

 

 

 

Содержание AIRE GUARDIAN AG8000

Страница 1: ...UCTION MANUAL Covered by one of more of the following U S Patent No 9 574 399 U S Patent No 10 195 979 Canada Patent No 2 895 016 Abatement Technologies Abatement Technologies Inc Georgia USA 1 800 63...

Страница 2: ...echnologies at 1 800 634 9091 US or 1 905 871 4720 Canada for assistance or to request a digital copy of this manual Table of Contents Important Safety Instructions 1 General Information 3 Transportin...

Страница 3: ...ways check to be certain no one is inside the unit before moving it Use only on level dry surfaces Do not use on slippery surfaces Do not put anything under the base or wheels of the AIRE GUARDIAN AG8...

Страница 4: ...AG8000 is designed to be used with the provided extension ladder only and should not be used with any other ladder Read all instructions within this manual as well as all danger caution and instructi...

Страница 5: ...items such as pipe or conduit D Handles A total of 8 handles are located at the corners of the mobile containment cart to assist in transport E Fiberglass extension ladder The AIRE GUARDIAN AG8000 was...

Страница 6: ...luded K External receptacles The unit comes with a 3 prong male receptacle for connection to a 120V 60Hz power source that is used to power the female receptacles on the unit There is also a receptacl...

Страница 7: ...with the remote variable speed knob that can be accessed while standing on the extension ladder R Internal GFCI receptacles One receptacle is designated for a PAS750 Portable Air Scrubber to allow re...

Страница 8: ...access projects P N AG8000 SA Once installed the Side Access Panel and the original clear polycarbonate panel are interchangeable An optional Extension can be purchased to reach ceiling heights of 12...

Страница 9: ...elp prevent over extending the header into the ceiling use the lowest clutch setting that is able to raise the header to the ceiling Turn hand crank clockwise to raise the header Turn hand crank count...

Страница 10: ...nto the POWER SUPPLY outlet located on the back side of the unit and the male end into a 110V 120V 60Hz single phase outlet The AG8000 comes equipped with a power cord wrap that is located below the P...

Страница 11: ...nd to maintain the minimum 75 angle required per OSHA requirements Opening and closing the top cover The top cover has a zipper down each long side and is secured by hook and loop on the short side ne...

Страница 12: ...20VAC VARIABLE SPEED DEVICE ONLY as shown in the picture above If the PAS750 or PRED750 unit is located external to the AG8000 ensure it is plugged into the outlet labeled FOR 120VAC VARIABLE SPEED DE...

Страница 13: ...n still be moved without crashing into any objects After raising the header close to the ceiling fine tune the positioning by aligning the arrow marker closest to the back of the unit with the ceiling...

Страница 14: ...tor Locate the pressure monitor mounting bracket on the inside back wall of the AG8000 Remove the faceplate from the RPM series pressure monitor by unscrewing the two small screws on the sides of the...

Страница 15: ...rovided hand crank or a power drill within a few inches of the ceiling Warning Be sure that the upper header will not crash into any device installed in the ceiling such as sprinkler heads sensors etc...

Страница 16: ...ean with a mild water based cleaner or soap and water Do not use hydrocarbon based cleaners Do not place items on the vinyl enclosure Do not subject the vinyl enclosure to sharp or abrasive objects Be...

Страница 17: ...eceptacles for general use 1 ea receptacle controlled by remove variable speed knob All receptacles rated 15 A entire circuit rated 15 A Scrubber speed control Remote variable speed control knob locat...

Страница 18: ...the purchase price of such goods AT will pay return transportation charges on returned goods not exceeding the transportation charges applicable to shipment from original destination unless the return...

Страница 19: ...18 EXTENSION LADDER WARNING AND INSTRUCTION LABELS...

Страница 20: ...19 AG8000 WIRING DIAGRAM Starting Serial Number C800019402727...

Отзывы: