Abatement Technologies AIRE GUARDIAN AG8000 Скачать руководство пользователя страница 17

16 

 

Top fabric 

Top fabric is included with unit and secured by hook 
and loop (P/N: AG8000TOP-FR).  

Fabric fire retardant standard 

ASTM-E84/NFPA701 

Ladder 

16' three-section fiberglass extension ladder with 
300 lbs weight capacity (P/N: LADDER03). 

Ladder weight 

40.5 lbs (18.4 kg) 

Exterior finish 

Anodized aluminum 

Header raising/lowering 

Mechanical system raises/lowers entire header with 
the provided hand crank or a power drill (not 
included with unit); 5/8" socket connection. 

Casters 

4 ea swivel, lockable, non-marking rubber casters. 

Pressure monitor mount 

Bracket and tubing port built into unit (RPM series 
pressure monitor sold separately). 

Receptacles 

External receptacles located on back of unit: 

  1 ea. three prong male receptacle to connect 

power (power cord not included) 

  1 ea. receptacle for general use 

  1 ea. receptacle controlled by remote variable 

speed knob located inside the unit 

Internal receptacles: 

 

3 ea. receptacles for general use

 

 

1 ea. receptacle controlled by remove variable 
speed knob

 

All receptacles rated 15 A; entire circuit rated 15 A. 

Scrubber speed control 

Remote variable speed control knob located inside 
unit allows for easy access control of an air scrubber 
(scrubber sold separately). 

Scrubber compatibility 

Unit is designed to accept the PAS750 air scrubber 
inside the unit; a PAS750 or PRED750 scrubber can 
be located external to the AG8000. 

Foam Gasket on Header 

1" wide x 1" tall gasket around header perimeter to 
seal against ceiling. 

Exhaust port 

10" diameter exhaust grille located on back of unit. 

Caddy cart 

Optional caddy cart assembly that attaches to 
AG8000 is available for locating the scrubber 
external to the unit (P/N: AG8000CADK). 

Side Access 

Optional Side Access Panel (P/N: AG8000-SA) 

Storage Cover 

Optional storage cover (P/N: AG8000SC) 

Extension 

Optional extension for ceilings up to 12'-2" and for 
increased header nominal opening to 60" L x 46" W 
(P/N: AG8000-EXT24) 

Patents 

Covered by one of more of the following: 
U.S. Patent No. 9,574,399 
U.S. Patent No. 10,195,979 
Canada Patent No. 2,895,016 

 

Содержание AIRE GUARDIAN AG8000

Страница 1: ...UCTION MANUAL Covered by one of more of the following U S Patent No 9 574 399 U S Patent No 10 195 979 Canada Patent No 2 895 016 Abatement Technologies Abatement Technologies Inc Georgia USA 1 800 63...

Страница 2: ...echnologies at 1 800 634 9091 US or 1 905 871 4720 Canada for assistance or to request a digital copy of this manual Table of Contents Important Safety Instructions 1 General Information 3 Transportin...

Страница 3: ...ways check to be certain no one is inside the unit before moving it Use only on level dry surfaces Do not use on slippery surfaces Do not put anything under the base or wheels of the AIRE GUARDIAN AG8...

Страница 4: ...AG8000 is designed to be used with the provided extension ladder only and should not be used with any other ladder Read all instructions within this manual as well as all danger caution and instructi...

Страница 5: ...items such as pipe or conduit D Handles A total of 8 handles are located at the corners of the mobile containment cart to assist in transport E Fiberglass extension ladder The AIRE GUARDIAN AG8000 was...

Страница 6: ...luded K External receptacles The unit comes with a 3 prong male receptacle for connection to a 120V 60Hz power source that is used to power the female receptacles on the unit There is also a receptacl...

Страница 7: ...with the remote variable speed knob that can be accessed while standing on the extension ladder R Internal GFCI receptacles One receptacle is designated for a PAS750 Portable Air Scrubber to allow re...

Страница 8: ...access projects P N AG8000 SA Once installed the Side Access Panel and the original clear polycarbonate panel are interchangeable An optional Extension can be purchased to reach ceiling heights of 12...

Страница 9: ...elp prevent over extending the header into the ceiling use the lowest clutch setting that is able to raise the header to the ceiling Turn hand crank clockwise to raise the header Turn hand crank count...

Страница 10: ...nto the POWER SUPPLY outlet located on the back side of the unit and the male end into a 110V 120V 60Hz single phase outlet The AG8000 comes equipped with a power cord wrap that is located below the P...

Страница 11: ...nd to maintain the minimum 75 angle required per OSHA requirements Opening and closing the top cover The top cover has a zipper down each long side and is secured by hook and loop on the short side ne...

Страница 12: ...20VAC VARIABLE SPEED DEVICE ONLY as shown in the picture above If the PAS750 or PRED750 unit is located external to the AG8000 ensure it is plugged into the outlet labeled FOR 120VAC VARIABLE SPEED DE...

Страница 13: ...n still be moved without crashing into any objects After raising the header close to the ceiling fine tune the positioning by aligning the arrow marker closest to the back of the unit with the ceiling...

Страница 14: ...tor Locate the pressure monitor mounting bracket on the inside back wall of the AG8000 Remove the faceplate from the RPM series pressure monitor by unscrewing the two small screws on the sides of the...

Страница 15: ...rovided hand crank or a power drill within a few inches of the ceiling Warning Be sure that the upper header will not crash into any device installed in the ceiling such as sprinkler heads sensors etc...

Страница 16: ...ean with a mild water based cleaner or soap and water Do not use hydrocarbon based cleaners Do not place items on the vinyl enclosure Do not subject the vinyl enclosure to sharp or abrasive objects Be...

Страница 17: ...eceptacles for general use 1 ea receptacle controlled by remove variable speed knob All receptacles rated 15 A entire circuit rated 15 A Scrubber speed control Remote variable speed control knob locat...

Страница 18: ...the purchase price of such goods AT will pay return transportation charges on returned goods not exceeding the transportation charges applicable to shipment from original destination unless the return...

Страница 19: ...18 EXTENSION LADDER WARNING AND INSTRUCTION LABELS...

Страница 20: ...19 AG8000 WIRING DIAGRAM Starting Serial Number C800019402727...

Отзывы: