Abatement Technologies AIRE GUARDIAN AG8000 Скачать руководство пользователя страница 4

 

GENERAL INFORMATION 

 

The AIRE GUARDIAN® AG8000 is a mobile containment unit designed to capture and 
contain  particulate  during  ceiling  access  work  on  ceiling  heights  up  to  10'-2".  Ceiling 
heights  up  to  12'-2"  can  be  reached  with  the  Extension  (P/N:  AG8000-EXT24,  sold 
separately). Additionally, a Side Access Panel (P/N: AG8000-SA, sold separately) can be 
installed to provide containment while doing wall access projects. Numerous user-friendly 
features help maintain superior levels of patient protection, worker safety, and productivity 
unmatched by any other hard sided cart. 

 

The AG8000 is designed to comply with ICRA requirements for projects requiring ceiling 
access and limited wall access. The unit and its accessories can be used to meet various 
mitigation activities which are required by the ASHE Infection Control Risk Assessment 
2.0  Matrix  of  Precautions  for  Construction,  Renovation  and  Operations  and  other 
regulating documents. These activities include, but are not limited to 

• Airborne dust dispersion prevention. 
• Neutral to negative pressurization. 
• Barriers that extend to the ceiling. 
• Indoor air exhaust that is HEPA filtered. 
• An impermeable temporary containment vessel. 

 

The  AIRE  GUARDIAN®  AG8000  is  designed  to  be  used  with  the  provided  extension 
ladder only and should not be used with any other ladder. Read all instructions within this 
manual as well as all danger, caution, and instruction labels affixed to the ladder.  
 
This  unit  should  be  used  in  conjunction  with  an  air  scrubber  in  order  to  meet  ICRA 
requirements where required. The AG8000 was designed to accept the PAS750 Portable 
Air Scrubber (sold separately) inside the unit, but has the flexibility to have an external air 
scrubber ducted to the unit's port (P/N: AG8000CADK, sold separately). 
 
This manual provides instructions on how to use the features of the AIRE GUARDIAN® 
AG8000, however, the procedure and/or order of operations in which it is used should be 
determined  by  the  healthcare  facility's  ICRA  plan. 

Any  procedural  information 

contained within this manual is to be taken as a suggestion only to help the user 
understand some of the design intent of the unit. 
 

TRANSPORTING BETWEEN FACILITIES 

The AG8000 should be secured to ensure that the 
unit does not roll during transport and transported 
in  its  normal  position  (resting  on  its  casters).  If 
extremely poor road conditions exist, or excessive 
shock 

and 

vibration 

are 

expected, 

take 

precautionary  measures  by  padding  the  unit  to 
provide impact absorption during transport.  

 

Additionally, secure the ladder to the floor with the 
included ratchet strap (P/N: 

HARDWRE209).

 

 

Содержание AIRE GUARDIAN AG8000

Страница 1: ...UCTION MANUAL Covered by one of more of the following U S Patent No 9 574 399 U S Patent No 10 195 979 Canada Patent No 2 895 016 Abatement Technologies Abatement Technologies Inc Georgia USA 1 800 63...

Страница 2: ...echnologies at 1 800 634 9091 US or 1 905 871 4720 Canada for assistance or to request a digital copy of this manual Table of Contents Important Safety Instructions 1 General Information 3 Transportin...

Страница 3: ...ways check to be certain no one is inside the unit before moving it Use only on level dry surfaces Do not use on slippery surfaces Do not put anything under the base or wheels of the AIRE GUARDIAN AG8...

Страница 4: ...AG8000 is designed to be used with the provided extension ladder only and should not be used with any other ladder Read all instructions within this manual as well as all danger caution and instructi...

Страница 5: ...items such as pipe or conduit D Handles A total of 8 handles are located at the corners of the mobile containment cart to assist in transport E Fiberglass extension ladder The AIRE GUARDIAN AG8000 was...

Страница 6: ...luded K External receptacles The unit comes with a 3 prong male receptacle for connection to a 120V 60Hz power source that is used to power the female receptacles on the unit There is also a receptacl...

Страница 7: ...with the remote variable speed knob that can be accessed while standing on the extension ladder R Internal GFCI receptacles One receptacle is designated for a PAS750 Portable Air Scrubber to allow re...

Страница 8: ...access projects P N AG8000 SA Once installed the Side Access Panel and the original clear polycarbonate panel are interchangeable An optional Extension can be purchased to reach ceiling heights of 12...

Страница 9: ...elp prevent over extending the header into the ceiling use the lowest clutch setting that is able to raise the header to the ceiling Turn hand crank clockwise to raise the header Turn hand crank count...

Страница 10: ...nto the POWER SUPPLY outlet located on the back side of the unit and the male end into a 110V 120V 60Hz single phase outlet The AG8000 comes equipped with a power cord wrap that is located below the P...

Страница 11: ...nd to maintain the minimum 75 angle required per OSHA requirements Opening and closing the top cover The top cover has a zipper down each long side and is secured by hook and loop on the short side ne...

Страница 12: ...20VAC VARIABLE SPEED DEVICE ONLY as shown in the picture above If the PAS750 or PRED750 unit is located external to the AG8000 ensure it is plugged into the outlet labeled FOR 120VAC VARIABLE SPEED DE...

Страница 13: ...n still be moved without crashing into any objects After raising the header close to the ceiling fine tune the positioning by aligning the arrow marker closest to the back of the unit with the ceiling...

Страница 14: ...tor Locate the pressure monitor mounting bracket on the inside back wall of the AG8000 Remove the faceplate from the RPM series pressure monitor by unscrewing the two small screws on the sides of the...

Страница 15: ...rovided hand crank or a power drill within a few inches of the ceiling Warning Be sure that the upper header will not crash into any device installed in the ceiling such as sprinkler heads sensors etc...

Страница 16: ...ean with a mild water based cleaner or soap and water Do not use hydrocarbon based cleaners Do not place items on the vinyl enclosure Do not subject the vinyl enclosure to sharp or abrasive objects Be...

Страница 17: ...eceptacles for general use 1 ea receptacle controlled by remove variable speed knob All receptacles rated 15 A entire circuit rated 15 A Scrubber speed control Remote variable speed control knob locat...

Страница 18: ...the purchase price of such goods AT will pay return transportation charges on returned goods not exceeding the transportation charges applicable to shipment from original destination unless the return...

Страница 19: ...18 EXTENSION LADDER WARNING AND INSTRUCTION LABELS...

Страница 20: ...19 AG8000 WIRING DIAGRAM Starting Serial Number C800019402727...

Отзывы: