ab Platinum Series Скачать руководство пользователя страница 4

4   User Guide for the Platinum Series Sound Processor

User Guide for the Platinum Series Sound Processor   5 

Platinum Series Sound Processor

Your audiologist will demonstrate the adjustable controls of the Platinum Series 
Sound Processor (PSP) and instruct you on appropriate settings . 

Figure 1: Platinum Series Sound Processor .

Program Control 

The program control, on the left side of the control panel, is used to turn the 
processor on and off, to select one of three programs, and to test the headpiece 
microphone .  The dots on the program selector represent different programs on  
the processor programmed by your audiologist .  The single   represents program  
# 1,    represents program # 2, and 

 represents program # 3 .  Your audiologist 

will determine how many programs are appropriate and instruct you on when to 
use each program .  The   position represents the headpiece microphone tester 
function detailed in the 

“Using the Platinum Series Sound Processor” 

section of this 

manual .  The (o) position will turn the processor off .

Volume Control

The volume control, indicated by 

 and located to the right of the program 

control, allows the user to adjust the loudness level of the processor .  Turning the 
control to the left (toward the smaller end of the scale) decreases the volume .  
Turning the control to the right (toward the larger end of the scale) increases the 
volume .  The volume range (how soft to how loud the volume can be adjusted) is 
programmed for you by your audiologist .

During your programming session, the audiologist will program your processor 
so that the 12:00 position on the volume dial represents your most comfortable 
loudness level . 

Processor Protection .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .   31
Implant Protection  .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .    .   32
Electrostatic Discharge  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 32
Airport Security Metal Detector  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 33
X-Ray Machines  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 34
Recommended System Operating and Storage Temperatures  .    .    .    .    .    .    .    .    .   34

Guidance and Manufacturer’s Declaration                                                              35

Compatibility Tables                                                                                                     39

Contact Us                                                                                                                       40

Содержание Platinum Series

Страница 1: ...ates All rights reserved Advanced Bionics AG Laubisrütistrasse 28 8712 Stäfa Switzerland 41 58 928 78 00 MANUFACTURED BY Advanced Bionics LLC California USA 1 661 362 1400 www AdvancedBionics com USER GUIDE By Advanced Bionics PLATINUM SERIES Sound Processor ...

Страница 2: ...User Guide for the Platinum Series Sound Processor PLATINUM SERIES By Advanced Bionics ...

Страница 3: ...oubleshooting Action Table 30 Caring for Your Cochlear Implant System 31 Cleaning 31 Labeling The symbols below are used on the labeling for the product and for transportation and their meanings are as follows CAUTION Federal law restricts this device to sale distribution and use by or on the order of a physician REF Model Number SN Serial Number EN60601 1 Classification Information Continuous Ope...

Страница 4: ...eadpiece microphone tester function detailed in the Using the Platinum Series Sound Processor section of this manual The o position will turn the processor off Volume Control The volume control indicated by and located to the right of the program control allows the user to adjust the loudness level of the processor Turning the control to the left toward the smaller end of the scale decreases the v...

Страница 5: ...s in place indicates a communication problem between the processor and implant For more information refer to the Using the Platinum Series Sound Processor section of this manual Additionally when the battery is near depletion and cannot power the processor the alarm will emit a slow beeping tone until the battery dies or is replaced Sensitivity Control The sensitivity control indicated by and loca...

Страница 6: ...use choking if swallowed Attaching the UHP Color Cap Align the color cap with your headpiece Gently press the cap and headpiece together The Color Cap will snap into place Removing the UHP Color Cap Insert the UHP Removal Tool into the slot above the headpiece cable connector Gently push the tool straight back to lift the color cap as shown below Figure 2 Removing the UHP Color Cap Auxiliary Jack ...

Страница 7: ...s are provided for use when carrying rechargeable batteries or the AA battery compartment WARNING Power supplies and battery chargers should be operated in an open area to ensure adequate airflow While no injury cases have resulted components may become hot during normal use or a fault condition If the device s temperature results in discomfort or pain when touched disconnect the power source and ...

Страница 8: ...he underside of the processor and the top of the battery Position the battery so the battery contact is toward the lever on the processor Guide the battery into the tracks on the processor Slide the battery onto the processor until it engages Do not force the battery into the processor The battery is designed to be inserted in only one direction To insert batteries into the AA battery compartment ...

Страница 9: ... AB 5620 into your car s power outlet connect the cable from the car adapter to the charger Figure 15 Car Charger Adapter To charge the lithium ion rechargeable batteries Place charger on a flat surface Connect the power supply cord to the power supply use only AB 7610 or AB 5620 Charger Car Adapter Connect the cable from the power supply to the charger Plug power supply cord into power outlet Fig...

Страница 10: ...e belt clip extend the life of headpiece cables when used as illustrated on the following page See Figures 18 20 Accessories Carrying Cases A variety of carrying cases are available for your processor Pediatric Kits are packaged with a belt and harness case Adult Kits come with a belt worn carrying case that is also available in additional colors and styles that can be purchased as accessories NOT...

Страница 11: ...for use with your auxiliary microphone IMPORTANT Please consult with your audiologist or AB prior to using an auxiliary microphone purchased from a third party vendor to determine if you have the appropriate cables and connectors and that the device in question is compatible with your system Telecoil Pickup The telecoil pickup provides an interface to audio induction loop assistive listening syste...

Страница 12: ...e microphone of the headpiece or auxiliary microphone Figure 21 Telephone Adapter Set up the telephone adapter as follows Unplug the handset cord from the telephone base Plug the short cord into the handset jack on the telephone base Mount the unit in a convenient location with the adhesive pad Plug the handset into the modular jack on the telephone adapter To use the telephone adapter plug the lo...

Страница 13: ...off position o 2 Check that a charged battery or an AA battery pack has been correctly inserted onto the processor 3 Adjust the volume so that the indicator notch on the control is all the way to the left 4 Check the position of the sensitivity control so that the indicator notch on the control is at the 12 00 position 5 Check that the headpiece connector is properly plugged into the headpiece jac...

Страница 14: ...ng those problems After trying the remedies below if the problem persists contact your programming center or AB for support No Sound Heard No Response From User Ensure that the cable is inserted into the processor and the headpiece is properly positioned Turn the processor off o and back to position or If the red LED indicator Does not blink or blinks once replace the lithium ion battery or batter...

Страница 15: ...this user guide Using another fully charged lithium ion battery align the slide track on the top of the replacement battery with the slide track on the underside of the processor Guide the battery onto the processor slide track and slide the battery until it Performing a System Check You can verify your system s operating status in three simple steps Step 1 Check battery charge status Step 2 Check...

Страница 16: ...ing it closed Align the slide track on the top of the replacement battery compartment with the slide track on the underside of the processor Guide the battery compartment onto the processor slide track and slide until it engages into place on the processor Do not force the battery compartment it is designed to be inserted in only one direction Forcing the battery compartment may jam or damage the ...

Страница 17: ...rgeable battery or AA battery pack If there are no blinks after replacement clean the contacts with a hearing aid brush or dry cotton swab If problem continues contact your cochlear implant center Red LED indicator continu ously blinks at one second intervals and or audible alarm if activated sounds at one second intervals Remove and re lock headpiece with implant Replace headpiece cable If proble...

Страница 18: ...ou at all times You might also hear a distorted sound caused by the magnetic field around the security scanner door or hand held screening wand Turning down the volume on your Processor before passing through security screening will ensure that those sounds if they occur are not too loud or uncomfortable To maintain and improve the life of the headpiece microphone we recommend that you store your ...

Страница 19: ...afety requirements of IEC 60601 1 2005 in ambient temperatures up to 33 C RF emissions CISPR 11 RF emissions CISPR 11 Harmonic emissions IEC 61000 3 2 Voltage fluctuations flicker emissions IEC 61000 3 3 Guidance and manufacturer s declaration electromagnetic emissions The Platinum Series system is intended for use in the electromagnetic environment specified below The customer or the user of the ...

Страница 20: ...tres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey b should be less than the compliance level in each frequency range c Interference may occur in the vicinity of equipment marked with the following symbol 6 kV contact 8 kV air 3 A m 3 V m Note 1 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and ...

Страница 21: ...pplies a range of accessories for use with the Platinum Sound Processor although not all accessories may be included in your sound processor kit or listed here For additional information regarding the Platinum Sound Processor or its ac cessory parts contact your clinician or Advanced Bionics Model Number Description AB 7250 Platinum Sound Processor AB 7500 Rechargeable Battery Pack AB 7510 AA Batt...

Страница 22: ...anced Bionics Platinum Series HiResolution HiRes 90K Neptune Harmony Auria Built Kid Tough and IntelliLink are trademarks of Advanced Bionics in the United States of America and other countries 029 M296 03 Rev B Advanced Bionics AG Laubisrütistrasse 28 8712 Stäfa Switzerland T 41 58 928 78 00 F 41 58 928 78 90 info switzerland AdvancedBionics com Manufactured by Advanced Bionics LLC 28515 Westingh...