Chapter 4
Description of Operation
4-5
Microprocessor Control
The 1391-DES is controlled by an 80C196KB microprocessor. Velocity
control, sequencing, fault logic, programming and option control is
performed by the processor. Current control is analog, as is the input
velocity command. The input command is fed through a 14 bit digital to
analog converter (13 bits/8192 resolution and a +/– sign bit).
Isolated Current Sensing
The Logic Control Boards receive current feedback from the Isolated
Current Sense Board. This circuitry provides the data used for current loop
closure.
Integral Circuit Breaker
The DC bus supply, input rectifier and power circuitry are protected against
overcurrents by an integral three pole magnetic circuit breaker. This is not
designed nor intended to meet NEC branch circuit requirements.
Line/DB Contactor
The three-phase incoming AC line is opened by the contactor whenever the
voltage on the contactor coil is removed. This operation in conjunction
with the shunt regulator reduces the bus voltage when the contactor is
disabled. The Logic Control Board remains energized except when voltage
is removed from the incoming isolation transformer.
Important: The 1391-DES contains a definite purpose contactor that is not
to be energized/de-energized more than twice an hour on a continuous
basis. The life of the contactor may be reduced considerably if the cycle is
exceeded. Contact your local Allen-Bradley Sales Representative for
additional information.
Power Driver Board
The Power Driver Board contains the circuitry needed to switch the power
transistor modules.
A Quad B Board
The A Quad B Board changes the resolver signal from a 1326AB or AD
motor into an encoder signal for use by a position controller (such as an
IMC S Class or 12x family controller).
Starting and Stopping
ATTENTION: The Enable control circuitry in the 1391-DES
includes solid-state components. If hazards due to accidental
contact with moving machinery or unintentional flow of liquid,
gas or solids exist, an additional hardwired stop circuit may be
required. Refer to the codes and standards applicable to your
particular system for specific requirements and additional
information. A device that removes AC input power when a
stop is initiated is an integral part of this drive. Refer to the
following individual stop mode explanations.
!
Содержание 1391-DES Series
Страница 2: ...User Manual 1391 DES Digital AC Servo Drive ...
Страница 10: ...Chapter 1 Introduction 1 10 End of Chapter ...
Страница 38: ...Chapter 5 Inputs Outputs and Switch Settings 5 8 End of Chapter ...
Страница 85: ...Chapter 8 Start Up 8 16 End of Chapter ...
Страница 89: ...Chapter 9 1326 AC Servomotors 9 4 End of Chapter ...
Страница 107: ...Chapter 11 Troubleshooting 11 12 End of Chapter ...
Страница 123: ...Appendix B Interconnect Drawings B 12 End of Appendix ...
Страница 127: ...Appendix C Cable Information C 4 End of Appendix ...
Страница 135: ...Appendix E Parameter Record E 8 End of Appendix ...
Страница 136: ...Notes ...
Страница 137: ...Notes ...
Страница 138: ...Notes ...
Страница 139: ...Notes ...
Страница 140: ...Notes ...
Страница 141: ...Notes ...
Страница 142: ...Notes ...
Страница 143: ...Notes ...
Страница 144: ...Notes ...
Страница 145: ...Notes ...
Страница 148: ...IMC is a trademark of Allen Bradley Company Inc ...