Installation Considerations
2–8
The following tables show tabular read range limits for the three
versions of the AdaptaScan Readers.
Table 2.A
Read Ranges, Catalog No. 2755-SN3
➀
Minimum Apparent Element Width
➁
Read Range
➂
Mils
mm
Inches
Meters
5
6
7.5
10
13
15
20
25
30
35
40
45
50
55
.13
.15
.19
.25
.33
.38
.51
.64
.75
.89
1.02
1.14
1.27
1.40
1.9 -
3.6
1.9 -
5.3
1.4 -
7.2
1.4 - 10.9
1.4 - 16.2
1.4 - 19.5
1.4 - 28.4
1.4 - 36.8
1.9 - 42.9
1.9 - 51.4
1.9 - 59.3
2.4 - 64.4
2.9 - 69.4
3.4 - 74.6
.048 - .092
.048 - .135
.036 - .183
.036 - .277
.036 - .411
.036 - .495
.036 - .721
.036 - .935
.048 - 1.09
.048 - 1.31
.048 - 1.51
.061 - 1.64
.074 - 1.76
.086 - 1.89
Table 2.B
Read Ranges Catalog No. 2755-SN5
➀
Minimum Apparent Element Width
➁
Read Range
➂
Mils
mm
Inches
Meters
5
6
7.5
10
13
15
20
25
30
35
40
45
50
55
.13
.15
.19
.25
.33
.38
.51
.64
.75
.89
1.02
1.14
1.27
1.40
1.9 -
4.7
1.9 -
7.3
1.9 -
8.9
1.4 - 14.0
1.4 - 19.5
1.9 - 21.8
1.9 - 29.7
2.4 - 36.2
2.4 - 42.5
2.4 - 51.5
3.4 - 56.9
3.9 - 61.9
4.4 - 67.9
5.4 - 71.6
.048 - .119
.048 - .185
.048 - .226
.036 - .356
.036 - .495
.048 - .554
.048 - .754
.061 - .919
.061 - 1.08
.061 - 1.31
.086 - 1.44
.099 - 1.57
.112 - 1.72
.137 - 1.82
Table 2.C
Read Ranges Catalog No. 2755-SN8
➀
Minimum Apparent Element Width
➁
Mils mm
Read Range
➂
Inches
Meters
5
6
7.5
10
13
15
20
25
30
35
40
45
50
55
.13
.15
.19
.25
.33
.38
.51
.64
.75
.89
1.02
1.14
1.27
1.40
1.4 -
5.7
1.4 -
8.2
1.4 - 10.7
1.4 - 16.0
1.4 - 21.0
1.9 - 25.4
2.4 - 34.3
3.4 - 42.2
5.4 - 50.2
6.4 - 55.6
7.4 - 62.1
8.4 - 65.4
10.4 - 69.0
11.4 - 72.5
.036 - .145
.036 - .208
.036 - .272
.036 - .406
.036 - .533
.048 - .645
.061 - .871
.086 - .107
.137 - 1.27
.163 - 1.41
.188 - 1.58
.213 - 1.66
.264 - 1.75
.290 - 1.84
Read Ranges
Read ranges based on four character Code
39 labels with a wide to narrow bar ratio of
2.6 to 1 and a print contrast ratio of .75 or
better. Read ranges will vary with bar code
symbol quality.
When scanning labels at an angle apparent
element width is less than the actual element
width.
Read ranges measured from front edge of
wiring base. Add .58 inches (.015 meter) for
the distance to the scan window.
➀
➁
➂
Read Range
Measured From This Point
Содержание Allen-Bradley 2755-SN3
Страница 1: ...User Manual AdaptaScan Bar Code Readers Cat No 2755 SN3 SN5 SN8 Allen Bradley...
Страница 78: ...European Union Directive Compliance C 2 Declaration of Conformity...
Страница 90: ...Glossary G 12 X X dimension The nominal dimension of the narrow bars and spaces in a bar code symbol...
Страница 95: ...PART NO P QUANTITY Q SUPPLIER V SERIAL S 27842 9106 0 0 0 1 2 3 4 5 6 7 8 9 0 5 9 00 38200 11413 8...