Overview
1–10
Reader Connector
The Reader plugs into this connector. All power and
communications with the Reader occurs through this connector.
I/O Module Sockets
Two sockets support any combination of the following input and
output modules. See specifications in Appendix A.
Description
Catalog Number
DC Output Module – rated at 3 to 60 VDC.
2755-OB5S
AC Output Module – rated at 12 to 140 VAC.
2755-OA5S
AC Output Module – rated at 24 to 280 VAC.
2755-OM5S
DC Input Module – accepts 3.3 to 32 VDC.
2755-IB5S
AC/DC Input Module – accepts 90 to 140 VRMS or VDC
2755-IA5S
AC/DC Input Module – accepts 180 to 280 VRMS or VDC
2755-IM5S
I/O Module Terminal Blocks
Wiring connections for the optional input or output modules.
Package Detect Terminal Block
Connects the contacts of a sensor, which detects the presence of a
package in the Reader’s scan area. The package detect can be either
an electronic (current sinking) or a hard contact type device. Most
applications use a photo-reflective type sensor. The package detect
starts and stops decoding and determines when messages are sent or
when outputs are energized.
Power – Indicator LED
Indicates normal operating and fault conditions.
Condition
Indicates:
Green
Power on.
Red
Polarity of the power connections is reversed. Wiring must be
corrected.
Off
No power.
Termination Switches
Terminates a DeviceNet and RS-422/RS-485 network. Terminate the
two devices furthest away from each other on a network by moving
the switch to the ON position.
Содержание Allen-Bradley 2755-SN3
Страница 1: ...User Manual AdaptaScan Bar Code Readers Cat No 2755 SN3 SN5 SN8 Allen Bradley...
Страница 78: ...European Union Directive Compliance C 2 Declaration of Conformity...
Страница 90: ...Glossary G 12 X X dimension The nominal dimension of the narrow bars and spaces in a bar code symbol...
Страница 95: ...PART NO P QUANTITY Q SUPPLIER V SERIAL S 27842 9106 0 0 0 1 2 3 4 5 6 7 8 9 0 5 9 00 38200 11413 8...