Publication 1738-IN002B-EN-E - November 2004
8
ArmorPoint 24V dc Input Modules, Series A
1738-IB8M8, -IB8M12, -IB8M23, -IV8M8, -IV8M12, and -IV8M23 Modules
Message size: 1 Byte
Troubleshoot With
the Indicators
7
6
5
4
3
2
1
0
Produces (Rx)
Ch7
Ch6
Ch5
Ch4
Ch3
Ch2
Ch1
Ch0
Channel status
Where: 0 = off, 1 = on
Indication
Probable Cause
Module Status
Off
No power applied to device
Green
Device operating normally
Flashing Green
Device needs commissioning due to missing, incomplete, or
incorrect configuration
Flashing Red
Recoverable fault
Red
Unrecoverable fault - may require device replacement
Flashing Red/Green
Device is in self-test
0
1
2
3
4
5
6
7
MOD
NET
1738-IB8M12/A
24V dc In
0
1
2
3
4
5
6
7
Module Status Indicators
43680
1738-IB8M12
Network Status Indicators
I/O Status Indicators