User’s Manual Version 1.3
Airolinx Wireless Serial-Ethernet Server
STW-601C
- 18 -
Fig. 21. TCP Client mode in link mode
4.2.6. Configuring Link Mode – UDP Mode
Operation: [Main]
Æ
[4 Serial Settings]
Æ
[1 Link mode]
Æ
[3 UDP]
STW can be configured in a UDP mode to establish connection using uni-cast or broadcast data from the
serial device to one or multiple host computers. Vice versa is also true. For example, The original RS-422/
RS485 bus is transferred and extended connecting distance by serial servers, The destination IP is
assigned by single IP or group IPs, The configuration is limited by the Local Listening Port (For example,
on the STW listening port is 4660 which receive data sending from the host computer)
STW can support up to 4-group IPs for UDP connection, if users needed.
Fig. 22. UDP mode in link mode
Note: UDP mode doesn’t support Virtual COM mode yet.
4.2.7. Configuring Serial for COM Port
Operation: