USER INSTRUCTIONS
Page 36
Aarrow Sherborne GSL CF
Under no circumstances must the stove be
operated if the glass is cracked, broken,
removed or open.
It is recommended that if the property is
occupied, the pilot be left on permanently.
This will keep the stove and its components,
including the ceramic coal / log set in a
warmer state and assist the lighting of the
burner. This in turn will reduce the chance of
condensation and any associated problems.
If the property is left unoccupied for a long
period of time, the pilot must be switched off.
The controls are located beneath the ash lip
at the base of the appliance, (See Fig. 31a).
NOTE:
Ensure burner control knob „B‟ is set
at maximum and the pilot control knob „A‟ is
set in the off position. (See Fig.31e).
Fig. 31a
Fig. 31b
B
A
Continue pressing down while turning knob „A‟
anti-clockwise to the small flame position, this
will activate the piezo and light the pilot.
Continue to hold down for a further 10 seconds
after the pilot has been lit, if the pilot does not
stay lit, repeat the procedure. When the pilot
stays lit release knob „A‟ at the small flame
position. (See Fig. 31c)
Fig. 31c
B
A
NOTE:
This lighting procedure does not have
to be carried out every time the stove is used,
provided the pilot is left alight.
Controls
TO IGNITE THE PILOT
Step 1.
First locate the pilot, it can be viewed in
the front right hand side of the coal / log bed.
Open the doors and look downwards through the
glass window, 50mm from the right hand side.
To ignite the pilot, turn the control knob „A‟ anti
-
clockwise towards the spark position (See Fig.
31b) until it stops, press down and hold in for at
least 5 seconds. (Only pilot gas flows).