background image

 
 
 

 

Manual Spectran V4 

 

 

Please  read  the  following  manual  carefully  before  using  your 
measurement device. This manual contains important information on how 
to properly operate this unit. 

 

 

1.3 

Aaronia AG 

    www.aaronia.de 

Содержание Spectran V4

Страница 1: ...al Spectran V4 Please read the following manual carefully before using your measurement device This manual contains important information on how to properly operate this unit 1 3 Aaronia AG www aaroni...

Страница 2: ...ower supply 12 4 OVERVIEW FRONT PANEL 13 4 1 Operating Equipment 13 4 2 Numeric block hotkeys 14 4 3 LC Display 15 4 4 The display shows 16 5 FUNCTIONAL DESCRIPTION 17 5 1 Technical data 17 5 2 Main m...

Страница 3: ...BV Preamplifier 33 5 3 23 GSMbst select GSM Burst Type 34 5 3 24 GSMdst GSM Slot Distance 34 5 3 25 Calib in preparation currently not usable 34 5 3 26 Bright Set display brightness 34 5 3 27 Logger s...

Страница 4: ...ther units 63 9 8 Correct settings for manual input measurement 63 9 9 Measurement of satellite TV 64 9 10 Measurement with a direct cable connection 64 10 SPECTRUM ANALYSIS BASICS 65 10 1 What is a f...

Страница 5: ...omination 77 Table 6 Power amplification factor and corresponding value in dB 77 12 2 Frequency tables 78 Table 7 Cell phone frequencies and providers 78 Table 8 German GSM900 frequencies and provider...

Страница 6: ...reserve ourselves the right to change our products specifications and documentations without any notice We have no obligation for revision of documents and manuals we delivered in the past 1 2 Warran...

Страница 7: ...ver expose the device to water Never use it outdoors while it is raining Otherwise the sensitive electronics could be damaged Avoid to high temperatures Do not leave the device on a heating in direct...

Страница 8: ...ent antenna c SMA cable 1m d Aaronia handle miniature tripod e Battery charger power supply with 4 adapters f SMA tool g SMA adapter h Aaronia 1300mAh Power battery already fitted i Aluminum carrycase...

Страница 9: ...ument s input with excessively strong signals which could permanently damage the highly sensitive circuitry The maximum allowable peak power at the input of the Spectran V4 is with activated PreAmplif...

Страница 10: ...ion Another function as volume control if the demodulator activated As a precaution before connecting anything to the audio output you should turn this volume control all the way down to zero to avoid...

Страница 11: ...k that can be connected to any device which offers an audio input e g PHONO CD LINE IN MIC etc Depending on the kind of input you may need an appropriate adapter cable which you can purchase from any...

Страница 12: ...apter see accessories list you can also operate Spectran devices in a car If you wish to operate Spectran via the power supply so please note that the power supply s circuitry will cause additional in...

Страница 13: ...lculation mode Right Left key select Exposure limits or W m display In Audio mode Right Left key Increase decrease center frequency by one RBW Up Down key Increase decrease RBW bandwidth Dot button In...

Страница 14: ...433 434 8 MHz 3 LTE800 780 862 MHz 4 ISM868 868 870 MHz 5 GSM900 921 2 959 6 MHz cell towers no cellphones 6 GSM18k 1800 1880 MHz cell towers no cellphones 7 UMTS 2110 2170 MHz cell towers no cellphon...

Страница 15: ...scheid 15 Manual Spectran V4 Overview front panel 4 3 LC Display 1 2 3 4 8 5 6 7 1 Batterie display 2 Bargraph 50 segments scala 3 Status field 4 Detector display 5 main display 6 Marker block 1 2 3 7...

Страница 16: ...Hold Modus activated Info display Shows the selected preset frequency range Using the keys 0 9 further presets UMTS DECT etc are available Display Mode status field Shows the current operation mode P...

Страница 17: ...le Time 10mS 10mS 5mS Filter bandwidth RBW 3kHz bis 50 MHz 1kHz bis 50MHz 200Hz only with option 002 bis 50 MHz Units of measurment dBm dB V V m A m W m dB V m W cm etc via PC software dBm dB V V m A...

Страница 18: ...or the currently selected menu entry the current setting is being displayed in clear text on the large info field at the top In our example it is the currently set center frequency 940 This way there...

Страница 19: ...see following description is preserved Thus you can quickly evaluate different frequency ranges with identical SPAN and without tedious re adjustment of start stop frequencies 5 3 2 Span frequency ra...

Страница 20: ...ange which gets sweeped is derived Tip Please note that a large frequency range will badly squeeze the display horizontally in the X axis and thus significantly reduces measurement accuracy Individual...

Страница 21: ...her signals However this gain in accuracy has its downside in the far longer sweep times 5 3 5 VBW video filter VBW Full VBW 100KHz The video filter is intended for visual smoothing of the signal The...

Страница 22: ...time setting the more precise the measurement at the cost of being more time consuming A Sw Time 20mS will activate the UNCALL sign 5 3 7 Reflev referenz level The reference level sets the position of...

Страница 23: ...ll signal sources The vertical bars of the individual signals are virtually being squeezed from top to bottom to fit all signals into the display Range Dynamics On the other hand when Range is set to...

Страница 24: ...uator is configured 5 3 10 PreAmp internal pre amplifier option 020 The optional internal extremely low noise PreAmp amplifies the applied signal by approx 15dB significantly enhancing the sensitivity...

Страница 25: ...odulation takes place around the center frequency bandwidth is controlled by the RBW setting This allows custom monitoring of individual small frequency ranges However note that the filter is slightly...

Страница 26: ...bug tracer option 015 The AudInd feature allows quick audio aided location of signal sources especially bugs or wiretaps In this mode a tone is being emitted whose strength and duration is proportiona...

Страница 27: ...r frequency hopping DECT to determine the crest factor or signal peak In MinMax mode signals are displayed with a hatched fill if the signal s corresponding graphic is wide enough to accommodate for t...

Страница 28: ...sweeps A very handy feature for suppressing casual interference or to smooth out the noise floor in order to achieve improved display of very weak signals Simply leave this mode on for say 24 hours an...

Страница 29: ...ludes the power density in W m including Autorange as well In effect this mode provides readings in three units at the same time if you also count in the Bargraph in dBm You can also use this feature...

Страница 30: ...ssible values are 1 2 or 3 5 3 17 MarkLvl set starting level for markers The MrkLvl setting determines the minimum signal level which will trigger the creation of markers exposure limit calculation an...

Страница 31: ...ent options are available Freq When set to Freq frequency the frequencies of the individual markers are displayed in a bigger size while the amplitudes signal levels in dBm are indicated in a smaller...

Страница 32: ...encies of up to 10GHz 12GHz Detection sensitivity in this mode is around 50dBm preamp on depending on frequency The maximum allowable signal level is approximately 10dBm Further information can be fou...

Страница 33: ...additional setting labeled 20dB to account for the optional external 20dB attenuator When using the attenuator this setting is mandatory for receiving correct field strength and power density measurem...

Страница 34: ...isplay SYNC Shows S at the decoder display NonDec Shows at the decoder display Col 0 Col 7 Colorcode 0 7 Shows 0 7 at the decoder display 5 3 24 GSMdst GSM Slot Distance With GSMdst you can change the...

Страница 35: ...e memory status field changes to RECORD the logger is now armed Press the menu key again to commence recording During the recording the number of log events left is displayed briefly in the pixel disp...

Страница 36: ...sferring large amounts of data from Spectran to the PC can take some time the dBm values are transferred with an accuracy of two decimal places Please note that the internal 64K memory can quickly be...

Страница 37: ...o Spectran s program memory SETUP s see below are also stored as programs Each program has its own specific program number This menu option allows you to recall and execute a particular program by its...

Страница 38: ...o configure a multitude of further options for each program among these a program description of up to 6 characters which will then be displayed in the info display just like e g GSM900 on hot key 5 B...

Страница 39: ...re is particularly useful for cleaning up a messed up configuration Attention Please make sure that no RF source disturbs this measurement Don t connect any antenna USB cable or power charger Only sta...

Страница 40: ...istance is felt slightly tighten the plug by using the SMA tool Again don t use an excessive force Never trigger the over torque protection The SMA tool has an over torque protection and starts slippi...

Страница 41: ...sive force As soon as you notice a resistance slightly tighten the connection using the SMA tool Again do not apply excessive force Do not trigger the over torque protection Screw by hand the SMA adap...

Страница 42: ...obtrusive or concealed measurements Simply attach the OmniLOG antenna to the Spectran s SMA socket Do not apply excessive force when you screw the antenna into position As soon as a significant amount...

Страница 43: ...u entry Activate the menu entry by pressing the Enter key or clicking the jog dial You are now being shown a list of antennas Using the up down arrow keys or the jog dial choose the connected antenna...

Страница 44: ...on All settings regarding antennas and cables are stored permanently even after switching the unit off Hence each time you use the unit you should make sure that the connected antenna and cable really...

Страница 45: ...come contaminated again just due to a trivial mains cable To avoid this shielded rooms must be equipped with so called mains filters Especially however the utilization of usual power cables for data t...

Страница 46: ...lf the center frequency If a correspondingly stronger signal is found there the previously measured one would be a harmonic With the current firmware Spectran already attenuates harmonics by approxima...

Страница 47: ...in Auto attenuator mode the sample time must be set to at least 100mS as otherwise intermittent erroneous level readings can occur specifically in the lower frequency ranges The delay can be avoided a...

Страница 48: ...is assumed in practice The reason behind this are further factors which can influence measurement inaccuracy Some of them are temperature dependence repeatability antenna errors modulation dependence...

Страница 49: ...the Jog dial the cursor can be positioned freely on the display The readout on the large main display as well as the exposure limit display and demodulation now correspond only to the current cursor p...

Страница 50: ...M900 cell towers The Status display should now show GSM900 Now you only need to choose the correct operation mode 8 4 Operation mode Spectrum analysis Now press the Enter key until the Display Mode st...

Страница 51: ...ion The Mode status field displays Hold As you have probably noticed the display constantly changes This is completely normal as the signal strength of the high frequency radiation also constantly cha...

Страница 52: ...es on its highest level When measuring a whole room this may well take a few minutes The value displayed now is the highest signal level that could be detected in the entire room Mostly you will be ab...

Страница 53: ...r of zeros without the Autorange function The practical Hold feature is also available in this mode for keeping the display smoother You can even display a percentage relative to an exposure limit As...

Страница 54: ...pectran also uses the non visible fractions of the main display value to calculate the figures related to exposure limits TIP You can download new and or updated exposure limits which are constantly u...

Страница 55: ...he dot key To change to PM please activate this feature by using the menu and select Demod Volume can be adjusted with the volume contro on the left In contrast to simple broadband detectors Spectran...

Страница 56: ...ng or crackling noise with many interruptions and morse like pulsing This is the so called control channel which is always active and beeps exactly at 1733 33Hz When one or more cell phones are active...

Страница 57: ...entire frequency range of the detector To take advantage of this sett the SwTime to 1mS using the menu By utilizing a high end state of the art Silicon Germanium SiGe technology detector chip we even...

Страница 58: ...ul measurement Still the intended application for the broadband option is operation as a power meter Its high temperature stability guarantees highly reproducible results The instrument s input impeda...

Страница 59: ...all check the UMTS frequency list in chapter 12 table 10 UMTS uses frequencies between 1 900 1 and 2 200 0MHz As we only want to measure the cell tower and not the cell phone we only need the so call...

Страница 60: ...utomatically Press the enter key once again A list of various filter bandwidths is displayed next Choose the 1MHz filter by using the up down arrow keys Confirm the new setting by again pressing the e...

Страница 61: ...ximums using the panning approach 9 2 Turbo Sweep for small frequency ranges Spectran automatically switches to a special Turbo sweep mode when certain conditions are met In this mode the second and a...

Страница 62: ...able at any time using the corresponding key It s even easier with our free PC analysis software MCS Here you can even attach info texts To recall the factory settings select Factor under the Setup me...

Страница 63: ...om model making to 5GHz WLAN are available at a mouse click Further information like channel number provider etc is displayed as well You can use the File manager in MCS to simply copy these parameter...

Страница 64: ...xistent risk of excess input levels particularly when utilizing high gain satellite dishes you should additionally add our optional 20dB attenuator by simply attaching it to the DC blocker 9 10 Measur...

Страница 65: ...ion has its own frequency range for exclusive use By assigning a separate frequency range for each application conflicts between different Road users can be avoided so that e g a cell phone cannot be...

Страница 66: ...at lane 1 you see nothing OK let s go on with lane 2 nothing either Now lane 3 OK there is some traffic going at 18 km h Continuing with lane 4 Nothing etc Until you have reached the last lane What ha...

Страница 67: ...MHz Also the signal strength of every frequency range is exactly stored Like this we also learn what signal strength was present on which frequency range Real world examples Let s assume that we want...

Страница 68: ...r bandwidth 2 320 2 450 130MHz usw We can now see all information concerning these three signal sources In practice this will look similar on the spectran display In this example we also have 3 main s...

Страница 69: ...ange from 0 6GHz there are 3 main signal sources b The frequency and signal strength of all 3 sources is exactly known So we have acquired a quick overview of what is active in this frequency range As...

Страница 70: ...n dB milliwatts dBm or dB microvolts dB V 11 2 Field strength V m A m and power density W m If you don t feed signals directly and instead perform measurements using an antenna you will mostly want to...

Страница 71: ...m 0 001 mW cm or 10 W cm 0 1 W m 0 01 mW cm as so on Table 2 Less frequently values in dBm m and dBW m can be found Conversion is similarly simple 1 W cm 10dBm m 20 dBW m or 10 W cm 20 dBm m 10 dBW m...

Страница 72: ...g formula applies 377 And the magnetic field H can be calculated like this 377 11 4 Calculating the wavelength in m To calculate the wavelength from the frequency use the following formula Here c corr...

Страница 73: ...e up range i e the minimum distance to the transmitter in which a realistic and sensible measurement can be achieved Example For a 900MHz cell phone the wavelength is 0 33 m Hence the close up range i...

Страница 74: ...0 000 000 45 0 000 000 22 0 000 001 3 0 000 000 33 0 000 000 18 60 0 000 000 045 0 000 000 022 0 000 000 13 0 000 000 033 0 000 000 018 We assumed the following center frequencies f here GSM900 f 900...

Страница 75: ...comparatively exact field strength measurement by simply using the Lambda X column This column presents a weighted average of all possible frequencies between 900MHz and 2 4GHz still giving you an ac...

Страница 76: ...m to V m and A m 0 000 1 W cm 0 019 4 V m 0 000 051 5 A m 0 001 W cm 0 061 4 V m 0 000 162 A m 0 01 W cm 0 194 V m 0 000 515 A m 0 1 W cm 0 614 V m 0 001 62 A m 1 W cm 1 94 V m 0 005 15 A m 10 W cm 6...

Страница 77: ...z 3 kHz 1 000 km 100 km VF 3 kHz 30 kHz 100 km 10 km VLF 30 kHz 300 kHz 10 km 1 km LF 300 kHz 3 MHz 1 km 100 m MF 3 MHz 30 MHz 100 m 10 m HF 30 MHz 300 MHz 10 m 1 m VHF 300 MHz 3 GHz 1 m 10 cm UHF 3 G...

Страница 78: ...nse expires 1 1 2007 10mW EIRP DECT Base station always transmits even when not handling calls 250mW EIRP DECT2 New generation of cordless phones DECT successor 25mW EIRP More extensive lists on www a...

Страница 79: ...providers Start Stop frequency abbreviation provider 1 710 0 1 725 0 GSM18K UL Milit r 1 725 2 1 730 0 GSM18K UL T Mobile 1 730 2 1 752 4 GSM18K UL O 2 1 752 8 1 758 0 GSM18K UL Vodafone 1 758 2 1 78...

Страница 80: ...2 120 2 UMTS DL Vodafone 2 120 2 2 130 1 UMTS DL Group 3G 2 130 1 2 140 0 UMTS DL e plus 2 140 0 2 149 9 UMTS DL MobilCom 2 149 9 2 159 8 UMTS DL O2 2 159 8 2 169 7 UMTS DL T Mobile D Alle Frequenzang...

Страница 81: ...hese limits are recorded in the Verordnung ber elektromagnetische Felder 26 BlmSchV and are mostly derived from the international recommendations As an approval for the compliance with these exposure...

Страница 82: ...35 MHz or approx 42 V m For E Net GSM1800 base stations this means that the electrical field strength needs to stay below 1 375 1800 MHz or approx 58 V m The respective allowed absolute maximums are a...

Страница 83: ...pendent For example a cellphone has a totally different device exposure limit than a TV broadcast station Here the allowed limits can easily vary by a factor of millions Still all device exposure limi...

Страница 84: ...limit calculation 13 External DC input 11 First measurement 50 First operational steps 40 fLow fHigh 19 20 FM 13 17 54 Freq 31 frequency modulation 54 GSM 17 26 34 GSM900 14 GSMbst 34 GSMdst 34 Hardwa...

Страница 85: ...13 Aaronia AG DE 54597 Strickscheid 85 Manual Spectran V4 Index Start frequency 59 Sweep 13 22 47 61 62 SwTime 22 63 Technical data 17 Tetra 14 Tips 61 UMTS 14 Unit 29 USB Connector 10 wavelength 72 7...