AD-4405 Weighing Indicator
Page
45
f28
determines the averaging time by 0.1second step.
f28 0
holds the data at
averaging start.
The key switch function as the HOLD key (Average start or release holding data)
is by pressing the
TOTAL
key while pressing the
ENTER
key.
The external input function of averaging start is
19
and hold release is
20
of
f13
,
f14
and
f15
. The function is accepted at the off to on edge of the external input.
Conditions of the Average and Release
Conditions of the Average and Release
Conditions of the Average and Release
Conditions of the Average and Release
The method to start/stop the average and release the hold state depends on the
f27
.
Condition
f27 1
f27 2
f27 3
Average start in the inhibit region
No
No
No
Average start with key switch (including unstable)
Yes
No
Yes
Average start with ext. input (including unstable)
Yes
No
Yes
Average start with command (including unstable)
Yes
Yes
Yes
Average start after passing the inhibit region and
stable
No Yes Yes
Weight is entering the inhibit region at averaging
Continue
Stop
Stop
Weight is entering to over at averaging
Pending
Stop
Pending
Hold key input at averaging
Stop
Stop
Stop
Release input from external input at averaging
Stop
Stop
Stop
Release command input at averaging
Stop
Stop
Stop
Hold key input at hold
Release
Release
Release
Release input from external input at hold
Release
Release
Release
Release command input at hold
Release
Release
Release
Weight is entering the inhibit region at hold
Continue
Release
Release
Weight is going to over at hold
Continue*
Continue* Continue*
Pending: Suspend the count up timer and do not average under the condition.
Release: Key, ext. input and command are effective at over display.
Continue*: Continue hold, but over display.
Key input and command in the ho
Key input and command in the ho
Key input and command in the ho
Key input and command in the hold state
ld state
ld state
ld state
Release hold and perform key function:
Keys:
TARE, ZERO, SETPOINT, TOTAL
Commands:
MT, MZ, HC
Continue hold and perform key functions
Keys:
NET/GROSS, Accumulation, Comparison start/stop
Commands: Other
commands
11. Hold Function